8 Katom St., Misgav Industrial Park, 2017400, Israel
Tel: +972-4-9951999; Fax: +972-4-9990287
PM0617.08 - CXE2000/CXE3000 CompletePBX Getting Started Guide (electronic version)
Page
6
of
7
that the port is configured as NT. Two fast green blinks Indicates that ISDN TE layer 1 is active.
Two fast yellow blinks Indicates that ISDN NT layer 1 is active. One green blink indicates that
ISDN TE layer 2 is active. One yellow blink indicates that ISDN NT layer 2 is active.
PRI port (
Fig. 4
): Solid green indicates that the port is configured as TE. Solid yellow indicates
that the port is configured as NT. Two fast green blinks Indicates that ISDN TE layer 1 is active.
Two fast yellow blinks Indicates that ISDN NT layer 1 is active. One green blink indicates that
ISDN TE layer 2 is active. One yellow blink indicates that ISDN NT layer 2 is active.
For more information about the unit status and port status LED indicators refer to the
Astribank
manual on the Xorcom Web site:
Additional Functionality Supported by the LCD Touch Panel
Internal Flash Drive for Restore Functionality
In addition to the standard
external
Rapid Recovery disk-on-key, all CXE series CompletePBX
models feature an
internal
device as well, which is attached to the LCD panel inside the
appliance.
Initially, factory defaults are stored on this device. Later on, you can create and store your own
customized backups here as well.
To activate the “restore” image function from the internal flash drive:
1.
Connect a monitor and keyboard to the server.
2.
Switch off the server.
3.
Switch on the server and press the Enter button on the LCD keypad until the "Loading from
internal flash..." message appears on the LCD.
4.
The Xorcom Rapid Recovery menu will be displayed on the monitor.
Additional LCD Panel Functions
Status
•
System Info
o
IP Address (shows all configured IP addresses)
o
Hardware Status (CPU utilization, temperature, etc. -- not implemented yet)
•
PBX Info
o
Blink port
Extension (blink Astribank port that corresponds to a given extension number)
Channel (blink Astribank port that corresponds to a given DAHDI channel
number)
XPD (blink Astribank ports that correspond to a given DAHDI XPD number)
SPAN (blink Astribank ports that correspond to a given DAHDI SPAN
number)
o
Active Calls (current number of active calls)
•
TwinStar Status (DRBD role, DRBD connection status)
•
RPS Status (status of power supplies in dedicated Redundant Power Supply unit, which
provides redundant power to Astribanks connected to the CXEn000 server)
Maintenance
•
Asterisk restart
•
DAHDI restart