Safe disposal of Lithium-ion batteries

 

Uninstalling a XOLTA battery should only be undertaken by an authorized electrician. 

 

Lithium-ion batteries must be treated as hazardous waste and not be disposed of with regular waste.

 

Special regulations apply to the transport of batteries, and these must always be observed.

 

A XOLTA battery that has reached the end of its functional life can be returned to the seller that originally  

 

sold the battery or to the dealer of a new industrial battery.

 

Disclaimer

 

We have taken every precaution to ensure that all information provided in this installationguide is correct and up to 

 

 

date. However, we assume no responsibility for damage to persons and property arising as a result of following 

 

 

recommendations and/or procedures described in this Guide. Furthermore, we assume no responsibility 

 

 

for any infringements of rights of third parties which may result from the use of this Guide.

 

The system is designed to assure that an installed XOLTA Outdoor BESS and all its associated functionalities  

 

behave safely under the predefined operating conditions. Nevertheless, please read all sections describing 

 

 

safety issues and precautions carefully before installation, operation, or performing service work on a XOLTA 

 

 

Outdoor BESS. Failure to do so could result in reduced system performance, damage to the system, personal 

 

 

injury or even death.

 

   

Cyber security

 

   

The XOLTA BAT-80 Outdoor BESS connects to local communications networks outside the control of

 

 

   

XOLTA. It is therefore the user’s sole responsibility to ensure that all appropriate measures are taken

 

 

   

to mitigate any unauthorized access to or interference with the product that can result in misuse or theft

 

 

   

of data. XOLTA and its affiliates are not liable for damages or losses related to such security breaches.

 

 

Copyright

 

This document and all information contained in the XOLTA User Manual are copyright 2022 by XOLTA A/S. 

 

 

All rights reserved. XOLTA reserves the right to make changes to the products described in this manual at 

 

 

any time without notice. This manual may be photocopied or otherwise distributed only to the extent that is 

 

 

necessary for the correct operation and installation of XOLTA Outdoor BESS.

 

Voiding of warranty

NOTE!

 

Please refer to XOLTA’s Terms and Conditions document delivered by XOLTA which governs the term and 

 

 

conditions for the product warranty.

 

The warranty for the product does not apply to, and XOLTA will not be responsible for, any defect, loss or 

 

 

damage to any product caused if:

 

•  The product covered is not continuously connected to the internet via LAN cable, meaning that XOLTA  

 

  cannot monitor the performance of said product;

 

•  The product covered has not been stored, transported, set up or installed in an appropriate and professional  

 

  manner in accordance with technical standards and regulations, in accordance with the relevant installation 

 

 

  manual of the product or the instructions of XOLTA;

 

•  The product covered has been operated contrary to its intended use or contrary to the instructions in the  

 

  relevant installation manual;

 

•  The product covered was out of service for a continuous period of more than six months after the initial 

 

 

  installation due to the fault of the purchaser;

 

•  The product covered has not been serviced properly and professionally according to technical standards  

 

  or XOLTA’s maintenance instructions;

Summary of Contents for BAT-80

Page 1: ...80 This guide provides you with the necessary information and step by step instructions for the mechanical and electrical installation of a XOLTA Outdoor BESS INSTALLATION INSTRUCTIONS All in one Bat...

Page 2: ...tallation requirements 11 5 Mechanical installation of the battery Mounting the battery base 12 Alternative cable routing 13 Lifting with forklift 15 Lifting with crane 15 Connnecting the battery syst...

Page 3: ...P04 855 Vdc max Main Power Input Output 3 x 400V AC Control Power input 1 x 230V AC Weight Approx 1100 kg Impact test IEC 62262 IK08 Dimensions in mm H2170 x W845 x D800 and the battery is intended t...

Page 4: ...the battery system at any time to ambient temperatures in excess of 50 C RISK OF ELECTRICAL SHOCK There are high voltages present on AC and DC cables There is a risk of death and serious injury due t...

Page 5: ...emergencies the actions to take are as follows LEAKAGE The battery pack might leak toxic electrolyte Electrolyte is corrosive and odorous ACTION Avoid any contact with the leaking liquid or gas In cas...

Page 6: ...way from the battery and contact emergency firefighters IMMERSION IN WATER Immersing the XOLTA Outdoor BESS in water risks causing a short circuit and damage to the battery system ACTION Do not try to...

Page 7: ...res are taken to mitigate any unauthorized access to or interference with the product that can result in misuse or theft of data XOLTA and its affiliates are not liable for damages or losses related t...

Page 8: ...rty An overvoltage has occurred in the power grid to which the product covered is connected The product covered has been exposed to force majeure including but not limited to in particular lightning f...

Page 9: ...attery Protection Unit installed Base keys Bolts 10mm Base frontplate Materials to be provided by the installer Concrete bolts mounting the base on foundation Inverter Power cable MAX 35 mm2 Control p...

Page 10: ...stallation requirements Minimum clearance space on all sides of the XOLTA Outdoor BESS should be observed when planning for installation see Figure x for requirements The required clearances ensure op...

Page 11: ...dation must be level this is to insure a nice visual look and best performance from the system Height of foundation should be minimum 150mm more if area is prone to flooding The foundation must be lev...

Page 12: ...ured to the rack base and the underlying foundation Use the 10 mm bolts to fix the battery unit onto the rack base The battery cabinets must be permanently fixed to the underlying foundation Moving th...

Page 13: ...es on the base will automatically ensure that the rack is lifted into the right position Press the cable towards the front and down so it is accessible for the subsequent electrical installation To av...

Page 14: ...480 mm x 4 Not futher than end of the rack Lifting with forklift If the ground is level around the installation site you can use a forklift to install the Battery Rack on the base Dismount the front...

Page 15: ...www xolta com 15 Press cable down x 4 Press cable down Calculate based on data sheet values for eye bolts on the previous page...

Page 16: ...VAC N 74A BAT 80 50 3 x 400VAC N 90A BAT 80 60 BPU power supply 1 x 230VAC N PE 10A per rack External power meter 3 x 400VAC N PE per meter Protective earthing Sizing according to power level above RC...

Page 17: ...s TERMINAL TERMINAL1 TERMINAL2 TERMINAL3 TERMINAL4 Function Controller PE Controller Neutral Controller power Inverter PE Voltage specification PE AC N L 240 VAC PE Conductor cross section BAT 80 25 3...

Page 18: ...ecting points inside the battery rack 4 8 Inverter power cables 1 3 BPU control power 9 Ethernet connection 10 Cable entry plate NOTE Please check phase order L1 L2 L3 400V 9 10 Install bolts in the b...

Page 19: ...80 Main board fuse XOLTA BESS ELECTRICAL PANEL XOLTA Rack Terminal 5 L1 XOLTA Rack Terminal 6 L2 XOLTA Rack Terminal 7 L3 XOLTA Rack Terminal 8 N Inverter 3 Phase Circuit Breaker with fuse Controller...

Page 20: ...he inverters of the Xolta C I are setup to follow the spe cific country region grid code e g over or under frequency response etc but for full grid code compliance they require a single and external N...

Page 21: ...hl connection refer to device manuals Refer to the document Schaltungsempfehlungen NA Schutz und Kuppelschalter for the list of recommended motors and coupling contactors for different power levels Th...

Page 22: ...n the frequency range of 49 5 50 5 Hz and after the mains frequency has been within this range for at least 180 s RELAY PROTECTION SETTINGS SET VALUE TIME LEVEL Overvoltage step 1 60s 253 V Overvoltag...

Page 23: ...zert nach VDE AR N 4110 PAmax PEmax Typ 1 EZE bzw Typ 1 Speicher an gem Betriebsmittel 135 kW Oder PEmax NAP 30 kW 1 PAmax PEmax alle Typ 2 EZE bzw Typ 2 Speicher 135 kW Oder PEmax NAP 30 kW 1 PAmax a...

Page 24: ...ection to occur only within the frequency range of 47 5 50 1 Hz and after the mains frequency has been within this range for at least 180 s For detailed information about ABB and Ziehl settings refer...

Page 25: ...experience any problems along the way please contact our support team on 45 7060 2017 You can change the language of the app in the menu in the top right corner It is possible to switch between Danish...

Reviews: