Failure To Follow All Electrical Safety Measures May Result in Serious Injury, 

Fire Or Death

All electrical work should only be performed by an

experienced, licensed electrician.

All XO units MUST be grounded for safe operation

 and

come equipped with a

  3 Prong molded cord/plug for that 

purpose.

NEVER remove or disable the 3rd prong with an adapter.

NEVER use an extension cord to operate your XO unit.

Your XO unit is built to operate on 115V 60Hz and 

should be plugged directly into a dedicated 15 amp

3 prong outlet.  If you are uncertain as to the 

voltage, amperage capacity or if the 3rd prong is

properly grounded - consult a licensed electrician.

To maximize the depth of the installation recess - 

your outlet should be mounted flush with the wall.

Your XO unit should not share the circuit with any other

electrical devices as this may cause overloading, 

overheating, blown fuses or tripping circuit breakers.  

In a worst case this can pose a fire hazard.

NEVER handle your XO unit in wet conditions as this 

can pose a severe danger of electric shock.

Exercise care when moving your XO unit to avoid 

damage to the electrical cord.  If the electrical cord of 

your XO unit becomes worn or damaged it must be 

replaced immediately by a qualified technician.

NEVER unplug your unit by pulling on the cord. 

Unplug by gripping the plug firmly and pull out 

straight from the outlet.

    

INDOOR USE ONLY:

XO Refrigerators, wine cellars and beverage 

centers described in this manual are rated for 

indoor use only.  

Your XO Unit was designed to operate in a 

room temperature ambient condition between

60  F and 90  F.    

Use in any area which is not temperature controlled

within that range, such as a garage or porch may

cause your XO unit to fail to function properly.

Use in any uncontrolled area or otherwise exposed 

to the elements is hazardous and voids the warranty. 

For outdoor installations - consult XO or your local

XO dealer regarding an outdoor rated model.

In regions where high humidity exists condensation 

may appear on the glass and/or gasket seals. 

For best operation, keeping the unit fully stocked

with product will reduce this.

  

SERVICE 

115V - 60 Hz - 1 phase

AMPS  

15 Amp Circuit Breaker

Requires a Dedicated Outlet
GFI required for Outdoor Installations
All electrical work must be performed by
a licensed electrician

7

Serious injury, fire or death...
Okay - 

electricity  - this is serious

o

o

Summary of Contents for XOU24BCGOA

Page 1: ...I worked really hard on this manual so please read it XOU24BCGOA UNIVERSAL FIT BEVERAGE CENTER...

Page 2: ...y a phone call away call 973 403 8900 Talk to one of our undercounter experts CONGRATULATIONS on purchasing your XO Before you proceed take just a moment to register your XO at Ensuring warranty cover...

Page 3: ...Installation Instructions S Reversing the Door Swing Integrated Panel Dimensions Optional Stainless Overlay Panel Leveling Your XO izes and Installation Dimensions 8 17 24 25 26 27 3 where things are...

Page 4: ...ly inspected all surfaces for any imperfections Have you reviewed this manual with the customer and explained the unit s operation and care Has the customer received copies of the literature and keys...

Page 5: ...5 XOU24BCGOA BEVERAGE CENTER 2 this is the model covered in this book record your serial number here in case you need it later ACCOMMODATES EUROPEAN ADA AMERICAN STANDARD CABINETRY...

Page 6: ...Failure to follow this step may cause problems Location Your XO unit should be located away from direct sunlight and heat sources stove heaters etc which may increase electrical consumption High or lo...

Page 7: ...unit to avoid damage to the electrical cord If the electrical cord of your XO unit becomes worn or damaged it must be replaced immediately by a qualified technician NEVER unplug your unit by pulling...

Page 8: ...AN T PULL THE SHELVES OUT If you need a little more space H D W X ADA EUROPEAN AMERICAN HEIGHT H Minimum Maximum WIDTH W DEPTH D TOE KICK PLINTH X 825mm min 890mm max 600mm 600m m 100mm min 150mm max...

Page 9: ...OVERALL DEPTH YOUR CHOICE OF CABINET HANDLES WILL ALSO ADD DEPTH 90o WITH THE DOOR OPEN AT 90 THE UNIT HAS A DEPTH OF 46 1 16 1170mm o 23 7 16 595mm Minimum 32 1 4 820mm Maximum 34 13 16 885mm 19 15 1...

Page 10: ...upper and lower hinge and then remove the door 4 Rotate the door 180 degrees top to bottom and place the hinges onto the screws 4 in Fig B Slide the slots of the hinge until fully seated against the...

Page 11: ...OR PANELS MUST BE FINISHED FRONT AND BACK TO PREVENT WARPING To ensure that the cabinet panel is completely hiding the door frame observe the frame dimensions as minimums You may decrease the size of...

Page 12: ...REVENT WARPING To ensure that the cabinet panel is completely hiding the door frame observe the side dimension as minimums and the center opening height as a maximum You may decrease the size of the c...

Page 13: ...OR TRIM BLOCK optional TRIM BRACKET included IMPORTANT Finish panel mounts to door even with the bottom of cabinets Legs are extended only enough to level unit The XOU24 A model is 32 1 4 Tall The sta...

Page 14: ...nto the nish panel no more than 1 2 12mm deep taking care not to drill through the panel 5 Using the ST4 30 self tapping screws provided fasten the panel to the door frame 6 Beginning at one corner re...

Page 15: ...tightly against the door and tighten both of the 2 set screws C with the hex key D Keep the hex key in a safe place for future use Two extra set screws are included in the hardware bag The Stainless...

Page 16: ...compensate for different height cabinetry your XO has leveling legs that can extend as much as 2 9 16 65mm When installing your XO with the leveling legs extended use the FOOT SLIDERS provided under t...

Page 17: ...ners until all four legs are seated firmly on the floor and the interior floor of the unit is level both front to back and side to side Failure to follow this important step may cause problems with pr...

Page 18: ...you are not using the vented toe kick that comes with the unit you must make provision for ventilation by cutting a slot 2 3 16 H x 19 5 16 W 55mm H x 490mm W With the door open using the screws provi...

Page 19: ...VERAGE CENTER XOU24BCGOA_ FRONT COOLING VENTS LEVELING LEGS CARBON FILTER CARTRIDGE replace every 3 to 6 months RECIRCULATION FAN GLIDE OUT GLASS SHELVES CONTROL PANEL REVERSIBLE DOOR HINGE REVERSIBLE...

Page 20: ...conds then revert to showing the compartment temperature To view the real time temperature press and hold the button for 5 seconds The interior temperature will flash in the LED Display for 5 seconds...

Page 21: ...will operate however it will not respond to your actions To initiate Sabbath Mode Press and hold both for 5 seconds The display will show either Sb or Sb On depending on the model you have to indicat...

Page 22: ...rn ON Press Hold for 3 Seconds to turn OFF Press to Silence Alarm Light Function Button Toggle Between 3 Light Functions L1 L2 L3 TEMPERATURE DISPLAY Indicator Light Cooling Mode ON Press to raise tem...

Page 23: ...TOTAL 22 TOTAL 2 LEVELS 2 DEEP 1 LEVEL OF 32 MODEL TOP SHELF LOWER SHELF BOTTOM 118 TOTAL Shelf capacities Avoid overloading Storing little or no product can cause excessive condensation 23 how many 1...

Page 24: ...the wine cooler power failure Most power failures are corrected within a few hours and should not affect the temperature of your appliance if you minimize the number of times the door is opened If the...

Page 25: ...r 1 4 turn to unlock Pull straight out to remove Align the tabs and insert the new filter Rotate filter 1 4 turn to lock in place P N XOUAIRFILTER 25 a breathe of fresh air for best results change eve...

Page 26: ...tightly closed and you have not recently added a large quantity of warm bottles it may be a mechanical issue Unplug the unit and call for service The alarm is beeping and LO is displayed on the contro...

Page 27: ...to assume obligations other than those expressly covered by this warranty Open box factory seconds scratch and dent floor models and commercial applications are excluded from these warranties Consume...

Page 28: ...28 XOU24BCGOAMANUAL2020...