  IMPORTANT SAFETY INSTRUCTIONS

  FOR RESIDENTIAL USE ONLY

  READ AND SAVE THESE INSTRUCTIONS

  PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.

  IMPORTANT: Save these Instructions for the Local Electrical Inspectors use.

  INSTALLER: Please leave these Instructions with this unit for the owner.

  OWNER: Please retain these instructions for future reference.

  Take care when using cleaning agents or detergents.

  Suitable for use in household cooking area.

  WARNING - To reduce the risk of fire or electric shock, do not use this fan with any 

Solid-State Speed Control Device.

  CAUTION - To reduce risk of fire and to properly exhaust air, be sure to duct air out-

side – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl 

spaces, or garages.

  CAUTION - For general ventilating use only. Do not use to exhaust hazardous or ex-

plosive materials and vapors.

  CAUTION - To avoid motor bearing damage and noisy and/or unbalanced impellers, 

keep drywall spray, construction dust, etc. off power unit.

  CAUTION - Please read specification label on product for further information and 

requirements.

  WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, 

OBSERVE THE FOLLOWING:

A.  Use this unit only in the manner intended by the manufacturer. If you have questions, 

contact the manufacturer.

B.  Before servicing or cleaning unit, switch power off at service panel and lock the serv-

ice  disconnecting  means  to  prevent  power  from  being  switched  on  accidentally. 

When the service disconnecting means cannot be locked, securely fasten a promi-

nent warning device, such as a tag, to the service panel.

  WARNING - TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

A.  Never leave surface units unattended at high settings. Boilovers cause smoking and 

greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B.  Always  turn  hood  ON  when  cooking  at  high  heat  or  when  flambeing  foods  (  i.e. 

ENGLISH

USA

Summary of Contents for XOP30S

Page 1: ...RA Manual de utilización USA F E XOP30S XOP36S NEED HELP Call our ventilation experts toll free al 800 966 8300 AVEZ VOUS BESOIN D AIDE Contactez nos experts au numéro gratuit 800 966 8300 NECESITA AYUDA Póngase en contacto con nuestros expertos a través del número gratis 800 966 8300 ...

Page 2: ...iginal purchaser for products purchased for ordinary home use in North America Should you require service for your XO product call a product service specialist at 800 966 8300 Improper Installation Service trips to the home to teach you how to use the product Resetting circuit breakers Damage caused after delivery EXPECT MORE FROM XO When buying any XO appliance you can be confident you have purch...

Page 3: ...s and vapors CAUTION To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit CAUTION Please read specification label on product for further information and requirements WARNING TO REDUCETHE RISK OF FIRE ELECTRIC SHOCK OR INJURYTO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you h...

Page 4: ...inguisher ONLY if 1 You know you have a Class ABC extinguisher and you already know how to operate it 2 The fire is small and contained in the area where it started 3 The fire department is being called 4 You can fight the fire with your back to an exit aBased on kitchen firesafety tips published by NFPA Proper maintenance of the Range Hood will assure proper performance of the unit INSTALLATION I...

Page 5: ...s after a prolonged use of the appliance C No food must be cooked flambè underneath the hood D The use of an unprotected flame is dangerous for the filters and could cause fires E Watch constantly the fried food in order to avoid the cooking oil flares up F Before performing any mainteinance operation disconnect the hood from the elec trical service The manufacturers will not to accept any respons...

Page 6: ...ation Engineering and reflect requirements for good venting performance with any ventilation hood Total Duct Run DUCT FITTINGS This Hood Must Use an 6 Round Duct It Can Transition to 3 1 4 x 10 or 3 1 4 x 12 Duct Use this chart to compu te maximum permissible lengths for duct runs to outdoors NOTE Do not exceed ma ximumpermissibleequiva lent lengths Maximum duct length 100 feet for range ho ods Fl...

Page 7: ...pe or Duct Tape INSTALL THE DUCTWORK NOTE To reduce the risk of fire use only metal ductwork 1 Decide where the ductwork will run between the hood and the outside 2 A straight short duct run will allow the hood to perform most efficiently 3 Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible 4 Install a roof or wall cap Connect 6 round metal...

Page 8: ... 8 Hood Specifications Product dimensions and clearance XOP30S XOP36S Front of hood Side of hood Top of hood Mounting height and clearance ...

Page 9: ...he air outlet Fig 1B or Fig 1C the wires set up in the relevant fairleads must be released by pulling the lever outwards as indicated in figure 2 phase 1 B Disconnect the 6 way quick coupling of the motor located inside of the hood as show in figure 2 phase 2 C The wires positioned inside of the hood are fasted with a cable tie Cut the cable tie as shown in figure 2 phase 3 Once transformation ope...

Page 10: ...sion prepare the air evacuation hole It is recommended to use an air evacuation pipe with the same diameter as the air outlet flange The use of a reduction could decrease product performance and increase noise I M P O R TA N T T h e r a n g e h o o d m u s t b e s e c u r e d t o w a l l studs or use drywall anchors capable of supporting 75 lbs ...

Page 11: ...ements 1 in the upper part of the hood Fig 3A 2 in the rear part of the hood Fig 3B 3 in the front part of the hood Fig 3C this position can only be used in the FILTERING version and has a fume suction system with front air re circulation The air evacuation flange is supplied with the rectangular shape X and circular shape Y Fig 3D Fig 3 ...

Page 12: ...e electric connection box positioned in the rear part of the hood as indicated in figure 4A see paragraph connection to the electric power supply If a rectangular air outlet pipe is used E the hood is already set up Fig 4B 1 If however a circular air outlet pipe is to be used F the 7 screws H must be removed along with the bracket X Fig 4C Fig 4 ...

Page 13: ...out all phases shown in figure 5A remove the 12 screws I Fig 5B that fix the motor bracket Y and turn the entire motor unit and position it as indicated in Fig 5C Put the motor bracket Y back in its seat and fix it with the 12 previously removed screws I Attention Whenever a circular air outlet pipe is to be used F the operation indicated in Fig 5D must always be repeated ...

Page 14: ...er as an accessory XORFK04 30 36 Before proceeding with the transformation from RANGE to FILTERING hood complete all phases shown in figure 6C Remove the 7 screws H and remove the bracket X Fig 6B Remove the 12 screws I Fig 6D that fix the motor bracket Y Rest the extracted motor unit on the work top and remove the 4 screws K which fix the motor to the flange Y Fig 6E Remove the 4 screws W that fi...

Page 15: ...ed screws K Fig 6H Put the bracket M fixed to the motor back in the same original position and fix it to the hood using the 4 screws W previously removed Fig 6I Put the motor bracket Y back in its seat and fix it with the 12 previously removed screws I Fig 6L Take the metal sheet L supplied with the product and close the hood air outlet hole with the 7 screws H Fig 6M ...

Page 16: ... 16 Fig 6 ...

Page 17: ...t be 2 wire with ground If the electrical supply does not meet the above requirements call a licensed electrician before proceeding Route house wiring as close to the installation location as possible in the ceiling or back wall Refer to Wiring Locations on page 18 Connect the hood wiring to the house wiring in accordance with local codes Grounding instructions The grounding conductor must be conn...

Page 18: ...wires of the hood to those of the power supply as described Fig 7 3 BLACK L line WHITE N neutral GREEN YELLOW G ground A double pole switch properly rated must be installed to provide the range hood power supply disconnection Connect the electrical conduit to the Field Wiring Compartment using listed onduit fittings Carry out the power supplly connection in accordance with the national electric co...

Page 19: ...power supply box refer to that indicated in Fig 8A 1 Loosen the two screws C Fig 8A 5 2 Break and remove the small circular metal sheet positioned in the upper part of the hood with the aid of a flat screwdriver Fig 8A 6 3 Take the electric connection box and fix it using the 2 screws C previously removed in the position indicated in Fig 8A 7 4 For the electric power supply connection refer to Fig...

Page 20: ...combined cooker stoves If a connection ductwork composed of two parts is used the upper part must be placed outside the lower part Do not connect the range hood exhaust duct air to the same duct air used to exhaust hot air or fumes from other appliances other than electrical 3 Connect the Ductwork ...

Page 21: ... 21 This product can be installed in 2 different ways Mounting the hood in the lower part of the shelf 1 type installation Fig 9 Mounting the hood on the wall 2 type installation Fig 9 Fig 9 ...

Page 22: ...on the lower part of the shelf Fig 10B considering the minimum distance from the cooker top Make 6 holes in the shelf respecting the measurements indicated Fig 10C Fix the 4 screws A without tightening them completely Fig 10A Position the hood under the pensile push towards the wall up to end run Fig 10A tighten fasten the 4 screws A and fix it definitively using the 2 safety screws B Fig 10 ...

Page 23: ... 23 Fig 10 ...

Page 24: ... it has been regulated fix it definitively using the 2 safety screws B Fig 11A For the various installations use screws and screw anchors suited to the type of wall e g reinforced concrete plasterboard etc If the screws and screw anchors are provided with the product check that they are suitable for the type of wall on which the hood is to be fixed Limited to installation on plasterboard walls mak...

Page 25: ... 25 Fig 11 ...

Page 26: ...nwards 2 Carbon filter kit XORFK04 The kit includes an air diverter A 2 screws and 2 expan sions plugs B 2 round filters C To convert this model from the sunction to the filtering version it is not necessary to use the air deviator A and the screws B Ductless Recirculating Option ...

Page 27: ... 27 Fig 2 The filters C must be applied to the suction unit inside the hood centering them inside of it and turning them 90 until they snap into place Fig 3 Put the aluminum panels back in place Fig 1 ...

Page 28: ... 28 USE If the apparatus is equipped with the following controls A LIGHT B OFF C SPEED I D SPEED II E SPEED III G MOTOR WORKING indicator ...

Page 29: ...o the room The filters are not washable or re usable and must be replaced at least once every four months The active carbon filter saturation level depends on the frequency with which the appliance is used the type of cooking performed and the regularity with which the anti grease filters are cleaned Cleanthecookerhoodfrequently bothinsideandoutside usingaclothwhichhasbeen dampened with denatured ...

Page 30: ... salt solutions disinfectants bleaches or cleaning compounds to remain in contact with stainless steel for extended periods Many of these compounds contain chemicals with may be harmful Rinse with water after exposure and wipe dry with a clean cloth Painted surfaces should be cleaned with warm water and mild detergent only ...

Page 31: ...spe cialized personnel Replacing halogen light bulbs In order to replace the dichroic lamps carefully remove the lamp from the lamp holder with the help of a small flat screw driver or a similar tool PLEASE NOTE In doing this operation please take care not to scratch the hood Replace the bulbs with new ones of the same type ...

Page 32: ... 32 XOP30S XOP36S ...

Page 33: ... 33 OPTIONS AND ACCESSORIES Model XORFK04 Ductless Recirculating Filter Kit ...

Page 34: ... 34 INSTALLATION PREPARATION Check installation hardware Locate the hardware package packed with the hood and check contents Aluminum filters ...

Page 35: ...ease particles They can be easily be removed for dishwasher safe cleaning Mounting Height from cooking surface 27 32 Dimensions 30 or 36 x 20 D x 11 Tall Duct Options and Electrical Requirements Duct size 6 or 3 1 4 x 10 Top or Rear Venting AC 120v 60Hz 4 35amp Options Optional recirculating kit if outside venting is unavailable Model XORFK04 XO is Exclusively Distributed by Eastern Marketing Corp...

Reviews: