CAUSING AIR TO CHANGE DIRECTION CAUSES TURBULENCE AND RESTRICTS FLOW IN
A SYSTEM.
IF USING FLEXIBLE METAL DUCT - INCREASE ALL MULTIPLIERS BY 50% (12 BECOMES
18 - ETC.)
THIS EASY TO USE WORKSHEET IS FOR 1000 CFM OR LESS.
UNDER “QTY USED” ENTER HOW OF EACH SECTION YOU WILL BE USING.
IN THE FIRST TWO ROWS - ENTER HOW MANY FEET OF EACH TYPE OF STRAIGHT DUCT
YOU WILL BE USING (I.E. FOR 20 FT ENTER 20, FOR 30FT ENTER 30).
ENTER THE NUMBER OF EACH TYPE OF TURN YOU ARE USING AND THE TYPE OF END CAP.
MULTIPLY ACROSS EACH ROW THE “MULTIPLIER” x “QTY USED” TO GET THE EQUIVALENT
FEET FOR THOSE COMPONENTS.
ADD UP ALL THE VALUES IN THE “EQUIVALENT FEET” COLUMN.
DUCT PIECE
DESCRIPTION
MULTIPLIER
QTY USED
EQUIVALENT
FEET
1’ of 8” Round Duct
1’ of 4“ x 14” Rect. Duct
8” 90 Degree Elbow
8” 45 Degree Elbow
4” x 14” 90 Degree
4” x 14” 45 Degree
4” x 14” x 8” Round
4” x 14” x 8” 90 Degree
8” Round Wall Cap w Damper
4” x 14” Wall Cap w Damper
8” Round Roof Cap
TOTAL EQUIVALENT FEET SHOULD BE LESS THAN 100
estimating total equivalent feet in
a duct
Summary of Contents for XOI3315KSE
Page 2: ......
Page 10: ...10 VENTED WALL EXHAUST ROOF EXHAUST typical installation examples...
Page 16: ...16 installation CONTINUED H E E M F 4 5 3...
Page 31: ...31 VENTIL VENT D CHAPPEMENT MURAL VENT D CHAPPEMENT DE TOIT exemples d installation typiques...
Page 37: ...37 suite de l installation H E E M F 4 5 3...
Page 52: ...52 VENTILADO ESCAPE DE PARED ESCAPE DE TECHO ejemplos t picos de instalaci n...
Page 58: ...58 instalaci n continuada H E E M F 4 5 3...
Page 65: ...65...
Page 66: ...66...
Page 67: ...67...
Page 68: ...3011000152300 00...