![background image](http://html.mh-extra.com/html/xo/xocyli-island-xocyli16bc/xocyli-island-xocyli16bc_manual_888112008.webp)
- 8 -
THIS HOOD IS DESIGNED TO USE A 6” ROUND DUCT -
IT MAY BE TRANSITIONED TO A 3-1/4” X 10” RECTANGULAR DUCT
NEVER REDUCE DUCT SIZE. UNDERSIZED DUCTING SEVERELY RESTRICTS AIR
FLOW AND HARMS PERFORMANCE.
(Example: the area of a 6” Duct is more than TWICE that of a 4” Duct)
KEEP DUCT RUNS AS SHORT AND STRAIGHT AS POSSIBLE.
AVOID USING FLEXIBLE METAL DUCTING IF RUN IS LONGER THAN 6’.
NEVER USE PLASTIC DUCTING.
USE SMOOTH BORE METAL DUCTING.
MINIMIZE THE NUMBER OF FITTINGS (see chart).
WHEN YOU MUST USE FITTINGS, TRY TO SEPARATE THEM WITH SECTIONS OF
3’ OR MORE OF STRAIGHT DUCT.
ALWAYS FOLLOW THE MANUFACTURER’S GUIDELINES FOR THE COOKING
EQUIPMENT YOU ARE VENTING.
IF MAKE UP AIR CONTROL DAMPERS ARE REQUIRED, POSITION THE SENSOR
IN A STRAIGHT RUN OF DUCT IDEALLY WITH 3’ OF STRAIGHT DUCT BETWEEN
EACH SIDE OF THE SENSOR AND A DUCT FITTING. REMEMBER TO INCLUDE
POWER AND CONTROL WIRING FOR THIS IN YOUR PLANS.
ADHERE TO ALL LOCAL BUILDING CODES AND ORDINANCES.
USE THE WORKSHEET THAT FOLLOWS TO HELP CALCULATE THE
TOTAL EQUIVILENT FEET
OF YOUR DUCT RUN.
TOTAL EQUIVILENT FEET SHOULD BE LESS THAN 100’.
a few simple rules to plan your
ductwork
1
1
12
7
14
8
33
2
4
24
24
33
Summary of Contents for XOCYLI ISLAND XOCYLI16BC
Page 2: ......
Page 11: ... 11 Front of hood Side of hood Top of hood DIMENSIONS ...
Page 14: ... 14 5 55 64 d X C 5 55 64 d 24 d 32 5 6 7 ...
Page 33: ... 33 Devant de la hotte Côté de la hotte Haut de la hotte DIMENSIONS ...
Page 36: ... 36 5 55 64 d X C 5 55 64 d 24 d 32 5 6 7 ...
Page 46: ...He trabajado mucho en este manual así que léalo XOCYLI ISLAND MODELOS XOCYLI16BC XOCYLI16SC ...
Page 55: ... 55 Parte delantera de la campana Lado de la campana Parte superior de la campana DIMENSIONES ...
Page 58: ... 58 5 55 64 d X C 5 55 64 d 24 d 32 5 6 7 ...
Page 68: ...3011000130801 00 ...