![background image](http://html1.mh-extra.com/html/xo/flex/flex_installation-instructions-manual_3545969053.webp)
XO FLEX – Installation instructions
Checking
the unit
53
Figure 74 – Adjusting the friction in the light head
Figure 75 – Adjusting the friction in the middle joint
ADJUSTING THE CUSPIDOR AND CUP FILLER
Water pressure for the cup filler and cuspidor is pre-adjusted.
If further adjustments are needed, please follow the steps below:
1.
Adjust the water pressure for the cup filler by turning the regulator – (1) in Figure 76.
•
Turn clockwise to increase pressure
•
Turn counter-clockwise to decrease pressure
To adjust the time the cup filler is activated, press the “configuration button” (see Figure 66) once,
select the menu “CUP/S” and set the time.
2.
Adjust the water pressure for the cuspidor by turning the regulator – (2) in Figure 76.
•
Turn clockwise to increase pressure
•
Turn counter-clockwise to decrease pressure.