Notice NOT 083
NXS 150
Rev : 00
Date : 13/10/05
USING
10.
DESCRIPTION OF THE FRONT PANEL
NXS 150
REPERE
DESIGNATION
F1
Welding current knob
F2 Power
terminal
+
F3 Warning
indicator
F4
Power ON indicator
F5 Power
terminal
-
11.
DESCRIPTION OF THE BACK PANEL
REPERE
DESIGNATION
B1 Input
cable
B2
ON/OFF main switch
12.
WELDING
Connect the power source to the main supply and the ground as explained in the chapter « Setting up » (
as
para -
6 and 7
). The NXS 150 unit automatically recognizes the value of the power supply.
Connect the ground cable and the electrode-holder to the appropriate power conne (
F2
) and - (
F5
)
according to the electrode polarity being used (refer to the electrodes manufacturer’s datasheets).
Start up the power source with the switch ON/OFF (
B2
).
When you start the power source, the orange indicator (
F3
) illuminates but goes out immediately if no failure has
been found.
The green indicator (
F4
) illuminates and indicates that the machine is live.
Adjust welding current with potentiometer (
F1
)
Place the electrode on the piece you have to weld in order to strike the arc.
Arc force control
Adjustment of arc force control is not possible, but it is optimised for welding with a large range of rutile and basic
electrodes.
USER’S MANUAL
Page
16/20
Summary of Contents for NXS 150
Page 1: ...NXS 150 Dual Voltage OPERATING MANUAL ...
Page 19: ...17 WIRING DIAGRAM ...