background image

Q UIC K INSTALLATIO N G UIDE

 

XR Se rie s  

Wire le ss Arra ys

 

Fe b rua ry 11, 2014

 

XR-2425H

 

Summary of Contents for XR-2425H

Page 1: ...QUICKINST ALLAT ION GUIDE XR Se rie s Wire le ss Arra ys Fe b rua ry 11 2014 XR 2425H ...

Page 2: ...re marks of their respective holders All rights reserved This document may not be reproduced or disclosed in whole or in part by any means without the written consent of Xirrus Inc Please see Warranty and License Agreements in the Wireless Array User s Guide Document Part Number 812 0085 006 Revision C February 2014 ...

Page 3: ...ies Appropriate tools bands screws and or anchors required for the desired mounting location not provided with the Array Antennas for up to four radios to be installed by a professional installer Antennas must meet these criteria Omni directional antenna gain must not exceed 5 dBi in 2 4 and 5 GHz bands Directional antenna gain must not exceed 12 1 dBi gain in 2 4 GHz band 11 2 dBi gain in 5150 53...

Page 4: ...Ethernet Network is 100 meters The PoGE Injector is not a repeater so its location will not increase this distance The XR 2425H can operate from a Wireless Distribution System WDS link However the unit will need to be configured via the Ethernet connection prior to mounting and power must still be supplied via the RJ 45 Ethernet connector Keep the unit away from electrical devices or appliances th...

Page 5: ...t with the four slotted flanges pointed towards the Array as shown below For Pole Mounting For Pole Mounting position the bracket with the four slotted flanges pointed away from the Array as shown below 5 Mount the Array on a Pole or Wall 5a Pole Mounting For pole mounting Xirrus recommends using metal straps not included with the Array The metal straps can be obtained from BAND IT IDEX Inc www BA...

Page 6: ...ng the Band It tool place the tool onto the strap Rotate the Band It tool so that it can pull the excess strap through the buckle and turn the crank until the strap is very tight Once the strap is satisfactorily tight rotate the Band It tool back so that the strap cannot slide back through the buckle Using the built in cutting tool on the Band It tool cut the excess strap ...

Page 7: ...ditional mounting security 5b Wall Mounting Place the Array in the desired location and mark the location of the bracket s two mounting holes on the wall as shown Drill and prepare the holes for the desired screw type In metal walls the holes may be tapped to the proper thread or alternatively the Array may be mounted with sheet metal screws For concrete walls a plastic anchor and screw are sugges...

Page 8: ...NOTE Be sure to configure the Array s IAPs to the proper bands 2 4 GHz and 5 0 GHz Each must match the band of the antenna to which it is connected Have your antennas installed by a professional installer as directed by the manufacturer Use Xirrus cables part number ANT CAB 195 10 MM Note that some antennas include integrated cables as part of the unit and these do not need separate cables 8 Conne...

Page 9: ...steps below before sliding the parts onto the cable Seat the O ring shown in red on the connector body gray at its RJ45 jack side Note the slots in the collar of the connector body and the matching tabs inside the connector ring Insert the connector body into the connector ring so that they mate Slide the sealing nut shown in green and the connector body assembly over the Ethernet cable as shown A...

Page 10: ...making sure that its tab clicks in place for a secure connection Seat the RJ45 connector correctly in the connector body Note the slotted track in the connector ring on the bottom of the Array and the matching tabs inside the connector ring in the waterproof connector assembly below Screw the assembly onto the Array s connector ring so that they mate securely Snug all the sections of the assembly ...

Page 11: ...rray s CLI or Web Management Interface WMI NOTE To use a 3x3 MIMO antenna with the XR 2425H connect to the 45 and 45 antenna outputs Do not use the connector marked V NOTE For some MIMO omni directional antennas where each of the individual antennas is dual band it does not matter which lead is connected to which connector on the Array For example the Xirrus ANT OMNI 2x2 02 has four antenna leads ...

Page 12: ...onnectivity it will automatically contact Xirrus for cloud based zero touch provisioning per your settings install the latest applicable license and upgrade the Array AP to the latest software version as appropriate XMS Enterprise Also available as a Cloud deployed solution XMS 9000 CL x This platform automatically detects and provisions new Xirrus devices deployed in your network via a similar ze...

Page 13: ...tio n Guide 11 Dimensions XR 2425H Dimensions Depth is 4 2 in 10 7 cm including the mounting bracket Weight 7 5 lbs 3 4 Kg Mounting Bracket Dimensions Depth 5 in 1 3 cm 11 4 in 28 9 cm 11 8 in 30 cm 13 3 in 33 7 cm 3 2 in 8 1 cm ...

Page 14: ... 947 7871 Toll Free in the US Fax 1 866 462 3980 www xirrus com The 2 GHz b g n radio operates in 2 4 GHz ISM band It supports channels 1 11 in US 1 13 in Europe and 1 13 in Japan It has two transmitters with a maximum total output power of 25dBm for 802 11b g n operation Output power is configurable to 5 levels It has three receivers that enables maximum ratio combining MRC The 5 GHz a n radio op...

Page 15: ...nless the device has been modified to be especially qualified for such use CAUTION Supplied watertight adapters must be used on all input output connections to the Array POWER WARNING Read the installation instructions before connecting the system to the power source WARNING Installation of the equipment must comply with local and national electrical codes WARNING This equipment must be externally...

Page 16: ... radiated power EIRP is not more than that permitted for successful communication Wi Fi Alliance Certification Federal Communications Commission FCC Statements Instructions FCC Declaration of Conformity Statement This device complies with Part 15 of the FCC Rules with operation subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept an...

Page 17: ...lp Use of a shielded twisted pair STP cable must be used for all Ethernet connections in order to comply with EMC requirements FCC Safety Compliance Statement The FCC with its action in ET Docket 96 8 has adopted a safety standard for human exposure to radio frequency RF electromagnetic energy emitted by FCC certified equipment When used with approved Xirrus antennas Xirrus XR products meet the un...

Page 18: ... Operation is subject to the following two conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne ...

Page 19: ... the regulatory requirements Declaration of Conformity Cesky Czech Toto zahzeni je v souladu se základnimi požadavky a ostatnimi odpovidajcimi ustano veni mi Směrnice 1999 5 EC Dansk Danish Dette udstyr er i overensstemmelse med de væsentlige krav og andre relevante bestemmelser i Direktiv 1999 5 EF Deutsch German Dieses Gerat entspricht den grundlegenden Anforderungen und den weiteren entsprechen...

Page 20: ...eślony mi Dyrektywą UE 1999 5 EC Portuguès Portuguese Este equipamento está em conformidade com os requisitos essenciais e outras provisões relevantes da Directiva 1999 5 EC Slovensko Slovenian Ta naprava je skladna z bistvenimi zahtevami in ostalimi relevantnimi popoji Direktive 1999 5 EC Slovensky Slovak Toto zariadenie je v zhode so základnými požadavkami a inými prislušnými nariadeniami direkt...

Page 21: ...ountry may change at any time Xirrus recommends that you check with local authorities for the current status of their national regulations for both 2 4 GHz and 5 GHz wireless LANs The following countries have additional requirements or restrictions than those listed in the above table Belgium The Belgian Institute for Postal Services and Telecommunications BIPT must be notified of any outdoor wire...

Page 22: ...1999 5 EC has also been implemented in those countries RF Exposure Generic Information The Xirrus Array products are designed to comply with the following national and international standards on Human Exposure to Radio Frequencies US 47 Code of Federal Regulations Part 2 Subpart J American National Standards Institute ANSI Institute of Electrical and Electronic Engineers IEEE C 95 1 99 Internation...

Page 23: ...er reducing your exposure then you can easily do so by reorienting antennas away from the user or placing the antennas at a greater separation distance then recommended FCC Guidelines for Exposure to Radio Waves The device includes a radio transmitter and receiver It is designed not to exceed the limits for exposure to radio waves radio frequency electromagnetic fields as referenced in FCC Part 1 ...

Page 24: ...ted in further reducing your exposure you can easily do so by reorienting antennas away from the user placing the antennas at a greater separation distance than recommended or lowering the transmitter power output Additional Information on RF Exposure You can find additional information on the subject at the following links FCC Bulletin 56 Questions and Answers about Biological Effects and Potenti...

Page 25: ...XR 2425H Quic k Insta lla tio n Guide Notes ...

Page 26: ...equest additional assistance please contact Xirrus Customer Support via Email at support xirrus com Live chat with one of the Xirrus Customer Support Representatives at http support xirrus com Call Xirrus at the following numbers United States and Canada 1 800 947 7871 US Toll Free or 1 805 262 1600 Direct Europe Middle East and Africa 44 20 3239 8644 Australia 1 300 947 787 Within Australia Asia ...

Reviews: