DEVICES 

Declaration of conformity 

Declaration of conformity according to the EC machinery 
directive (2006/42/EG, app. II 1. A). 

 
The manufacturer, 

 

BellandTechnology AG 

 

Kühlenfelser Straße 47 
D-91278 Pottenstein 

 

declares sole responsibility that the machine 
 

 

Name: Xioneer VXL GO 

 

Model: 1 

 

Year of manufacture: 2021 

 
complies with all the relevant provisions of the machinery 

directive 2006/42/EG. 
 

The machine also complies with all provisions of the following 
directives: 
 

 

Directive 2014/30/EU relating to electromagnetic 
compatibility.  

 

Directive 2014/35/EU Low Voltage Directive. 

 
The following norms have been applied: 

 

EN 55014-1:2017: Electromagnetic compatibility - 
Requirements for household appliances, electric tools 
and similar apparatus - Part 1: Emission. 

 

EN 55014-2:2015: Electromagnetic compatibility - 

Requirements for household appliances, electric tools 
and similar apparatus - Part 2: Immunity. 

 

EN IEC 61000-3-2:2019: Electromagnetic compatibility 

 

Part 3-2: Limits - Limits for harmonic current emissions 

(equipment input current ≤16 A per phase)

Summary of Contents for VXL GO

Page 1: ...Jul 21 V1 1 Page 1 20 DEVICES DEVICES Xioneer VXL GO Starter Kit for Support Material Dissolving...

Page 2: ...afety instructions and warnings 7 Preparation 9 Accessory Checklist 9 Setup 9 Filling and Operation 10 Operation 11 Controls 11 Recommendations for materials and temperature 12 Insert parts 13 Remove...

Page 3: ...read this manual carefully It gives you all the necessary information about the operation of the starter kit and helps you avoid potential hazards Tip This symbol shows you important tips Caution This...

Page 4: ...complies with all provisions of the following directives Directive 2014 30 EU relating to electromagnetic compatibility Directive 2014 35 EU Low Voltage Directive The following norms have been applie...

Page 5: ...supply systems for equipment with rated current 16 A per phase and not subject to conditional connection The following other technical norms and specifications have been applied None Head of technical...

Page 6: ...inserted print objects will be dissolved by the movement of the heated washing solution Specifications Rated Voltage Frequency 230 V AC 50 Hz EU plug Max power consumption Ca 850 W Max temperature 60...

Page 7: ...le and do use a grounded plug Do not touch the openings of the heating stirring rod while it is in operation Keep the starter kit away from children and only operate it supervised It may only be opera...

Page 8: ...ease seek medical advice If you have inhaled the detergent seek a well ventilated environment and ensure unobstructed breathing If you persistently feel unwell seek medical advice If swallowing occurs...

Page 9: ...following parts included 1x PP container 1x PP perforated lid 1x heating stirring rod 1x pliers 1x siphon pump 1x safety glasses 1 pair of nitrile gloves 1 coil of VXL 70 or VXL 90 support material 1...

Page 10: ...mometer symbol and adjust with the arrow buttons until the desired temperature maximum 60 C has been reached Press and hold the arrow buttons to adjust the temperature faster After pressing the clock...

Page 11: ...switching the rod on and off On the left and right of this there are green arrow buttons for increasing right arrow and decreasing left arrow the temperature and time The middle row contains two gree...

Page 12: ...g solution regularly Check with the manufacturer for the tolerated dissolving temperatures of the model material As a guide keep the value 20 30 C below the glass transition temperature Tg of your mod...

Page 13: ...of the support structure mechanically always wear the provided tight fitting safety glasses Splintering parts of the support structure can damage eyes or lead to cuts Make sure to wear suitable prote...

Page 14: ...ually at first before increasing significantly This is the moment where you should use a new washing solution After removing the printed parts they must be cleaned from the washing solution on all sid...

Page 15: ...ools down to room temperature During the emptying process make sure to perform the following steps Switch off the heating stirring rod and let the washing solution cool down to room temperature Have a...

Page 16: ...of the siphon pump Tip The washing solution can be disposed of down the drain Inform yourself whether special local wastewater regulations apply in your region Tip The emptying can be split into seve...

Page 17: ...the sleeve over the rod again and fasten it with a slight clockwise rotation until snapped in Close the container with the perforated lid and introduce the heating stirring rod via the big opening in...

Page 18: ...solution bath Solution Switch off the rod Refill with water and wait until the solution bath cools down Subsequently you can switch the rod on again and continue with the dissolving process Code E3 C...

Page 19: ...od and let it cool down Always remove the power plug before this step Subsequently take off the sleeve and verify whether openings of the sleeve or rod are blocked The openings must be free and the st...

Page 20: ...n For additional information further questions or supply of detergent you can contact us under BellandTechnology AG K hlenfelser Str 47 91278 Pottenstein Germany Website www xioneer com Email wecanhel...