49
1≤P4-08≤P4-04
P4-08=2
P4-04=4
Segment
1
Segment
2
Segment
3
Segment
4
start
P4-03.1=1
P4-08=0
or
P4-08>P4-04
P4-08=8
P4-04=4
start
Segment
1
Segment
2
Segment
3
Segment
4
end
1≤P4-08≤P4-04
P4-08=2
P4-04=4
Segment
1
Segment
2
Segment
3
Segment
4
start
4.3.3.4 Change step signal (/CHGSTP)
Parameter
Name
Setting
Meaning
Range
P5-35
Change
step signal
/CHGSTP
n.0000
Defaulted is not distribute to input
terminal. Refer to chapter 4.4.3.
Range:
0000-0014.
Distribute
to
input
terminal through P5-35.
When it set to 0001, it
means input from SI1.
4.3.3.5 Skip present segment signal (/ZCLAMP)
Parameter Signal name
Setting
Meaning
Range
P5-31
Skip the
present
segment
/Z-CLAMP
n.0000
Defaulted is not distribute to input
terminal.
Range:
0000-0014.
Distribute
to
input
terminal through P5-31.
When it set to 0001, it
means input from SI1.
In different Step-Changing modes, the function of skipping the current segment will have different effects, as
follows:
Change step
mode
P4-03 n.xx□x
Skip the
present
segment
Actions
0
/Z-CLAMP
Cancel current segment, execute the next segment at once
1
Cancel current segment, execute the next segment when the
change step signal is ON
2
Cancel current segment, execute the next segment at once
3
Cancel current segment, set the F2-09 again
4
The current segment is cancelled and executes the next segment at
the falling edge of signal /CHGSTP
5
The current segment is cancelled, and the corresponding segment
is executed after other segments are selected
6
When the current segment is cancelled, executes the selected
position segment at the rising edge of signal /CHGSTP
When using the skip current segment function, the SI terminal assigned by P5-31 needs to be triggered by the
rising edge.
4.3.3.6 Set segment through communication
Parameter
Meaning
Default
setting
Unit
Range
Modify
Effective
F2-09
Set the segment
number through
communication
0
-
0
~
35
Anytime
At once