EDFA-1550-8×22-HP-1U
32
8
22
FC/APC or SC/APC or E2000
EDFA-1550-8×23-HP-1U
33
8
23
FC/APC or SC/APC or E2000
EDFA-1550-8×17-HP-1U
27
8
17
FC/APC or SC/APC or E2000
EDFA-1550-8×18-HP-1U
28
8
18
FC/APC or SC/APC or E2000
EDFA-1550-8×19-HP-1U
29
8
19
FC/APC or SC/APC or E2000
EDFA-1550-8×20-HP-1U
30
8
20
FC/APC or SC/APC or E2000
EDFA-1550-8×21-HP-1U
31
8
21
FC/APC or SC/APC or E2000
EDFA-1550-8×22-HP-1U
32
8
22
FC/APC or SC/APC or E2000
EDFA-1550-8×23-HP-1U
33
8
23
FC/APC or SC/APC or E2000
6. OPERATION INSTRUCTION
6.1 Boot Show:
Please put the plug in the
outlet with AC220V, and the LCD panel will show
“SYS_INITIALIZATTING Wait……” , after system
initialization, the LCD panel will show as Figure
(1) in page “0”. The LCD panel shows
“SYS.NORMAL V6.5”.
6.2 Product Type:
Figure (2) in page “1.1”.
6.3 Product Serial Number:
Figure (1)
page "2"
6.4 Optical Power Input:
Figure (1)
page"3". Displaying the current optical power
input. When the optical power input is less than
-10dBm, it displays " -99dBm".
6.5 Checking Output Optical Power:
Figure (1)page"4", displaying the current
optical power output.
When the optical power output is less than
20dBm, it displays " -99dBm".
6.6 Device Temperature:
Figure (1) page
"5".
6.7 Fan Status:
Figure (1) page"6" and
page "4". The fan, a total of three kinds of
working state can be adopted .In the current
page, click the" "key to change the working
state, while in the "AUTO" state, when the
device internal temperature is higher than
45
℃
, the SCM will automatically open the
chassis fan to cool, and it will not close until the
temperature dropped to 35
℃
.
6.8 Parameters of Pump Laser:
Figure (1) page "7". In the current page click the button " " to check the parameters
5