xiMU - Technical Manual Version 2.10
83
6.3.
Safety instructions and precautions
This chapter describes safety instructions and precautions valid for xiMU cameras and special considerations regarding XIMEA
board level cameras. In order to avoid harm or damage your xiMU camera, please handle it like described in this manual, paying
special attention to the cautions shown in the following table:
6.3.1.
Disassembling
Do not disassemble the camera except lens mount adapters (see
3.3.5 MU181 Lens Mount Adapter
There are no switches or parts inside the cameras that requires any kind of mechanical adjustment. Please note that the warranty
is voided by opening the camera housing.
6.3.2.
Mounting / Screwing
Use only the designated threaded holes for mounting the camera. Please note the camera / bracket drawings in sections
Dimensional drawings (without Lens Mount Adapter),
and
6.3.3.
Connections
Use only recommended connectors and cables. Please check the system requirements described in
6.3.4.
Power supply
Use only the recommended electrical power supply via the USB cable, see
The I/O connection is not usable for powering the camera.
6.3.5.
Environment / protect against water
Use camera in acceptable environment only, please note the descriptions in
Protect the camera against contact with water. Do not let camera get wet.
Damages may be caused by:
•
Overheating
•
Contact with water
•
Operation in an environment with condensing humidity
•
Mechanical shock
6.3.6.
Recommended light conditions.
Do not expose the camera to light sources with intense energy, e.g. laser beams or X-ray.
Light intensity or exposure time exceeding the saturation of the sensor may damage the sensor irreparably. This may occur e.g. in
the following situations:
•
High-energy laser light hitting the sensor directly
•
Bright light sources hitting the sensor directly (burn-in)
•
Camera is exposed to X-rays
The warranty does not cover damaged cameras caused by X-ray applications or too much light / laser light.