Xilver Droplet User Manual Download Page 6

 

 

 

 

11 

Normal mode HSI 

Compact mode HSI 

DMX  ch 

Function 

Decimal  

Percent 

Description 

Reset 

0 - 249  
250 -255 

0 - 97 
98 - 100 

Reserved for special functions 
Hold for 5 seconds to reset the Droplet

TM 

 

Pan 

0 - 255 

0 - 100 

Position from 0° - 360° 

Tilt 

0 - 255 

0 - 100 

Position from 0° - 260° 

Strobe 
Frequency 

0 - 4 
5 - 204 
205 - 255 

0 - 2 
3 - 80 
81 - 100 

Full on, no strobe 
Strobe linear from 1Hz to 25Hz 
Strobe linear from 25Hz to 50Hz  

Hue 

 

1 - 42 
43 
44 - 84 
85 
86 - 127 
128 
129 -170 
171 
172 - 212 
213 
214 - 254 
255 

 

1 - 16 
17 
18 - 32 
33 
34 - 49 
50 
51 - 66 
67 
68 - 82 
83 
84 - 99 
100 

Primary colors if Saturation channel has value 255 
Red 
Red <> Yellow 
Yellow 
Yellow <> Green 
Green 
Green <> Cyan 
Cyan 
Cyan <> Blue 
Blue 
Blue <> Magenta 
Magenta 
Magenta <> Red 
Red 

Saturation 

0 - 255 

0 - 100 

Linear fading from white to saturated color chosen via 
the Hue channel  

Intensity 

0 - 255 

0 - 100 

Linear fading from 0 – 100% output 

DMX ch 

Function 

Decimal  

Percent 

Description 

Reset 

0 - 249  
250 -255 

0 - 97 
98 - 100 

Reserved for special functions 
Hold for 5 seconds to reset the Droplet

TM 

 

Pan 

0 - 255 

0 - 100 

Position from 0° - 360° 

Tilt 

0 - 255 

0 - 100 

Position from 0° - 260° 

Speed 

0  
255 

0 - 100 

Full speed of pan and tilt movement 
Slowest pan and tilt movement 

Pan fine 

0 - 255 

0 - 100 

Fine Positioning of the pan within an angle of 1,41° 

Tilt fine 

0 - 255 

0 - 100 

Fine Positioning of the tilt within an angle of 1,02° 

Strobe 
Frequency 

0 - 4 
5 - 204 
205 - 255 

0 - 2 
3 - 80 
81 - 100 

Full on, no strobe 
Strobe linear from 1Hz to 25Hz 
Strobe linear from 25Hz to 50Hz  

Strobe 
Duration 

0 - 255 

0 - 100 

Linear from 0 – 100% with steps of 1,6% 

Hue 

 
 

1 - 42 
43 
44 - 84 
85 
86 - 127 
128 
129 -170 
171 
172 - 212 
213 
214 - 254 
255 

 
 

1 - 16 
17 
18 - 32 
33 
34 - 49 
50 
51 - 66 
67 
68 - 82 
83 
84 - 99 
100 

Linear fading through all saturated colors if the 
Saturation channel has value 255 
Red 
Red <> Yellow 
Yellow 
Yellow <> Green 
Green 
Green <> Cyan 
Cyan 
Cyan <> Blue 
Blue 
Blue <> Magenta 
Magenta 
Magenta <> Red 
Red 

10 

Saturation 

0 - 255 

0 - 100 

Linear fading from white to saturated color chosen via 
the Hue channel  

11 

Intensity 

0 - 255 

0 - 100 

Linear fading from 0 – 100% output 

 

 

 

 

12 

2.3. 

Accessories 

 

Standard supplied 
 
Lenses 

When delivered the has a beam angle of 10°. Additional supplied with each Droplet

TM 

are two lenses, 

one with a beam angle of 18° and the other with a beam angle of 30°.  
 
Replacing a lens 
To replace a lens of the  Droplet

TM 

first take of the front hood by pulling the front hood. The existing lens 

or lens dome can be taken out. When you want to have a larger beam angle and the lens dome take 
out the black synthetic ring. Than first place the 18° or 30° lens and than the lens dome. The lenses 
should be placed with the uncurved side pointing to the Droplet

TM  

and the curved side to the outside. 

 

Extension shaft 

The head of the Droplet

TM 

can be taken of of the base and can be extended this way. Xilver B.V. 

supplies optional extension shafts for this purpose.  
The following sizes of extension shafts can be delivered out of stock:  

?

 

15cm (5,91inch) 

?

 

25cm (9,84inch) 

?

 

35cm (13,78inch) 

Other sizes can be delivered on request. 
 
The extension shaft is standard colored in silver (RAL 9006), black (RAL 9005) or white (RAL 9003). 
On request it can be delivered in any RAL color or even in custom color. 
 

Warning:

 A Droplet

TM 

 with extension shaft may only operate hanging (max. extension length: 55cm / 

21.65inch) in vertical direction or standing (max. extension length: 20cm / 7.87inch). 

 
Cables 

The Droplet

TM 

 is standard delivered without cables and connectors. On request  the Droplet

TM  

can be 

pre-wired with Data and power cable with the desired connector. 
 
 

2.4.  Place of usage 

 
The Droplet

TM 

 is mentioned for indoor use only! The product may not be exposed to water or extreme 

hot or cold environments.  
The Droplet

TM 

should not be used in humid environments. The minimum operation temperature  of the 

Droplet

TM  

is 0°C (32°F) and the maximum is 40°C (104°F). The minimum storage temperature of the 

Droplet

TM 

is -10°C (14°F) and the maximum is 60°C (140°F). 

 
In case of building-in the base of the Droplet

TM 

make sure there is enough ventilation so the unit 

becomes not overheated. 
Should the Droplet

TM  

get overheated in case of a too high environment temperature or not enough 

ventilation, the Droplet

TM  

will limit its light output to protect the LEDs. 

 

Warning:

 during the use of the Droplet

TM 

make sure that no persons or objects get in contact with the 

unit in a direct way. The pan and tilt travel should always be free to make sure the unit doesn’t looses its 
position. 

Summary of Contents for Droplet

Page 1: ...lectrical Safety for Luminaires Maastricht March 2003 Ing R Buskens 2003 Xilver B V All rights reserved No part of this document may be reproduced stored in a retrieval system or transmitted in any fo...

Page 2: ...ightning fast color changes Impressive white and full color strobes can be controlled by the frequency and duration channel Prepared for installation low power consumption light weight small size univ...

Page 3: ...n 10mm 0 39 inch Fixed installation There are 2 slotted holes in the base plate 1 is reserved for the power cable s and the other is reserved for the data cable s Before mounting the plate put the wir...

Page 4: ...ould have a unique identity This identity can be given by the DMX address settings There is a dipswitch on the bottom of the fixture to set the DMX address Warning when changing the dipswitch settings...

Page 5: ...can choose a color with the Hue channel RGB mode RGB is stands for Red Green and Blue Each of these colors use one channel via this channel you can adjust the output of the concerned color To vary the...

Page 6: ...Additional supplied with each Droplet TM are two lenses one with a beam angle of 18 and the other with a beam angle of 30 Replacing a lens To replace a lens of the Droplet TM first take of the front...

Page 7: ...of some parts of the fixture can rise up to 80 C 176 F Warning Do not stare into the beam of the Droplet TM the intense light output can cause injuries to your eyes 14 3 TERMS OF WARRANTY By normal us...

Page 8: ...14 F Max 60 C 140 F Dipswitch functions Dipswitch 1 2 3 4 5 6 7 8 9 10 11 12 Function DMX LSB DMX MSB Mixing Method Address Range Reserved Address setting binary H S I Normal Position 0 1 1 2 4 8 16...

Reviews: