ZC702 and ZVIK Getting Started Guide
13
UG926 (v6.0) December 17, 2013
Default Jumper and Switch Settings
Default jumper positions are shown in
and listed in
.
Table 1-1:
Default Switch Settings
Switch
Position
Setting
Callout
SW10
(JTAG chain input select two-position DIP switch)
1
Off
9
2
On
SW12
(two-position DIP switch)
1
Off
2
2
Off
SW15
(two-position DIP switch)
1
Off
2
2
Off
SW16
(five-position DIP switch)
1
Right
1
2
Right
3
Right
4
Right
5
Right
SW11
(power slide switch)
Off
8
1
Down
Table 1-2:
Default Jumper Settings
Jumper
Function
Default Position
Callout
HDR_1 X 2
J5
CFGBVS short to GND
OFF
4
J6
POR Master Reset
OFF
1
J7
USB 2.0 USB_VBUS_SEL
ON
6
J8
XADC GND L3 Bypass
OFF
2
J9
XADC GND
ON
2
J10
ARM HDR J41 pin 2 to VADJ
OFF
7
J11
UCD9248 U32 ADDR52 RESET_B
OFF
4
J12
FMC_VADJ_ON_B
ON
4
J13
UCD9248 U33 ADDR53 RESET_B
OFF
3
J14
UCD9248 U34 ADDR54 RESET_B
OFF
5
J15
CAN BUS COMMON-MODE CANH HDR
ON
7
J43
Ethernet PHY HDR
ON
7
J44
USB 2.0 USB_RESET_B
OFF
7
J53
CAN BUS COMMON-MODE CANL HDR
ON
7
J56
JTAG HDR J58 pin 2 3.3V SEL
OFF
9
J65
XADC_VCC5V0 = VCC5V0
ON
2