TYPE:
The 5 types of EQ that can be used are: parametric (PEQ), low shelf (LO-SHF), high shelf

(HI-SHF), 1

st

degree all-pass (AP-1), and 2

nd

degree all-pass (AP-2).

FREQ:

The EQ center frequency ranges from 20Hz to 30kHz in either 1Hz steps or 1/36 octave

steps. The frequency steps can be selected in the

System Menu

.

Please refer to page 21

for more details.

BW:

The EQ bandwidth ranges from 0.02 to 3.61 octaves in steps of 0.01 octave.

The

equivalent Q value is automatically shown besides the octave value.

For 1

st

degree

all-pass (AP-1) filter, the bandwidth will sets the phase shift at the centre frequency.

This

phase shift is gradually changed from 180 degrees above the centre frequency to the

specified value.

LEVEL:
The EQ level (or gain) ranges from -30.00dB to +15.00dB in 0.25dB steps.

Input Graphic Equalizer

GEQ#:
The graphic equalizer has 31 bands of equalization from 20Hz to 20kHz. This control

selects one of the 31 available bands.

The frequency corresponding to each band is also

shown.

LEVEL:
The GEQ level (or gain) ranges from -30.00dB to +15.00dB in 0.25dB steps.

BYPASS:

This control will un-bypass (Off) or bypass (On) the entire GEQ for this channel.

Input/Output Crossover

TYPL:

The 3 available filter types for the low frequency crossover point (high pass) are:

Butterworth, Linkwitz Ri ley or B essel.

FRQL:

The f ilter c ut-off frequency for the low frequency crossover point (high pass) ranges from 20

to 30kHz in either 1Hz steps or 1/36 octave steps. The frequency steps can be selected in

the

System Menu

.

Please refer to page 21 for more details.

SLPL:
The filter slope for low frequency crossover point (high pass) ranges from 6 to 48dB/octave.

If the selected filter type is Linkwitz Riley, the available slopes are 12, 24, 36 or 48
dB/o ctave only.

TYPH:

Summary of Contents for XP Series

Page 1: ...XP Series Loudspeaker Management System QUICK START GUIDE XILICA Audio Design...

Page 2: ...XP XP XP PC XP LCD 2 X 3 ENTER Recall Store Config 2 3 4 Copy General Secure Enter Menu Cursor Menu Control LED Menu Control Mute Menu Cursor Level 15 40 db Cursor 0 1300 ms Menu Control EQ 1 8...

Page 3: ...3 100ms RELEASE 200ms 3200ms Menu ON OFF Menu Name A Z Enter Enter Menu Store 30 Cursor 12 Enter 2 XP LEVEL Menu Control Level POL Menu Control Cursor 180 DELAY Menu Control Cursor Cursor 0 1300ms EQ1...

Page 4: ...nu Menu Cursor On Off Name Menu 5 Menu Control Menu Menu Menu Menu Menu Cursor Recall Enter Store Enter Menu 2 3 4 Config Enter Menu Menu None Stereo 2 way Stereo 3 way Stereo 4 way Copy Enter Menu Me...

Page 5: ...Menu Menu Menu Menu Secure PASSWORD Enter Enter 2 XP PC XP PC Menu Control Speed Speed Xilica China Unit 14 10 F Kwai Cheong Centre 50 Kwai Cheong Road Kwai Chung Hong Kong 50 10 14 Tel 852 2604 9382...

Page 6: ...gether Inputs and Outputs are linked separately 4 Channel Menu LED Indicates the activated channels for data modification 5 Peak Level LED Indicates the current peak level of the Signal Signal 12dB 6d...

Page 7: ...uttons are lit for the linked channels Any modification of the data for the selected channel will be applied to the linked channels as well To cancel the linking simply deselect the desired channel wh...

Page 8: ...steps Input Graphic Equalizer GEQ The graphic equalizer has 31 bands of equalization from 20Hz to 20kHz This control selects one of the 31 available bands The frequency corresponding to each band is...

Page 9: ...s from 0 3 to 1ms in 0 1ms steps then ranges from 1 to 100ms in 1ms steps RELEASE The compressor release time can be set at 2X 4X 8X 16X or 32X the attack time RATIO The compressor ratio is the slope...

Page 10: ...ups A program can be stored using this menu The old program with the same program number will be replaced Once the program is stored in the flash memory it can be recalled at a later time even after p...

Reviews: