Config - Device Configuration 
 
 
 
 

 

SYSTEM-SETUP MENU:Config 
MODE:2-Way 
  

 

 

 

MODE - configures the mode of operation.  

  

Mode: 

Out 1 

Out 2 

Out 3 

Out 4 

Out 5 

Out 6 

None 

Any Any Any Any Any Any 

Stereo 

2-Way 

In1 In1 In2 In2 Any Any 

Stereo 3-Way 

In1 

In1 In1 In2 In2 In2 

 

The unit assigns the Input source for the corresponding outputs when the 
Mode of Configuration is selected. The crossover point parameters like the 
filter type, cut-off frequency and slope have to be configured manually in 
the 

Xover

 Menu in each Output menu. 

 

*Note: The configuration mode configures the input sources when selected. 
The user can change the source afterwards if desired. It does not keep the 
configuration in memory. 

 
 

Copy - Copy channels 
 
Copy Channels from the source to the target. When the Source and 
Targets are both Inputs or Outputs, all audio parameters will be copied. 
When one of the Source or the Target is an input while the other is an 
output, only the Level, Polarity, Delay and EQ are copied. 
 

 

SOURCE - Channel to be copied from. 

 
 
 

O1:XXXXXX Copy 
SOURCE:In1 

 

TARGET - Channel to be copied to. 

 
 
 

O1:XXXXXX Copy 
TARGET:In2 

DCP-3060 User's manual - Page 18 

Summary of Contents for DCP-3060

Page 1: ...DCP 3060 Loudspeaker Management System User Manual XILICA Audio Design...

Page 2: ...ing pool and the like 6 CLEAN ONLY WITH DRY CLOTH Unplug the unit from the wall outlet before cleaning Do not use liquid cleaners or aerosol cleaners Use a damp cloth for cleaning 7 DO NOT BLOCK ANY V...

Page 3: ...ket or table The unit may fall causing serious injury to someone and serious damage to the appliance A unit and cart combination should be moved with care Quick stops excessive force and uneven surfac...

Page 4: ...Panel Functions 7 4 0 Rear Panel Functions 9 5 0 Powering Up the Device 10 6 0 Operating the Device 11 6 1 Input menus 11 6 2 Output Menus 13 6 3 System Menus 17 7 0 Quick Reference 20 8 0 PC Control...

Page 5: ...elay polarity 6 bands of parametric EQ per channel multiple crossover selections and full function limiters Precise frequency control is achieved with its 1 Hz resolution Inputs and outputs can be rou...

Page 6: ...put Multiple Crossover types with Full Function Limiters Precise Level Polarity and Delay CPU and DSP upgrade via PC Individual Channel Buttons with Linking capability 2 Line x 16 Character Backlit LC...

Page 7: ...puts and Outputs are linked separately 3 Peak Level LED Indicates the current peak level of the Signal Signal 12dB 6dB 3dB Over Limit The Input Over LED references to the device s maximum headroom The...

Page 8: ...Next cursor in the menu Screen Enter Sys Speed Enter is used only in the System Menu to proceed with selected actions Sys enters the System Menu from the main menu Speed modifies delay and frequency...

Page 9: ...Main Fuse T200mA 250V Slow blow type 3 Power switch Controls power On Off 4 RS232 a standard female DB9 socket A straight through cable is required for PC connection 5 Option slot Option slot for futu...

Page 10: ...60 firmware version After the initialization process is finished the DCP 3060 displays its main screen XILICA DCP 3060 INITIALIZING XILICA DCP 3060 P01 XXXXXXXXXXXX The screen shows the current progra...

Page 11: ...the linking just press any other Menu key or the Sys key after releasing the held key 6 1 Input menus Each of DCP 3060 input channels has a separate Menu key There are 3 menus for each input channel S...

Page 12: ...be selected in the System Menu I1 XXXXXX EQ FREQ 1000Hz BW EQ Bandwidth Ranges from 0 02 to 2 50 octaves in steps of 0 01 octave steps for PEQ The Q value is automatically shown beneath the octave val...

Page 13: ...nnel of the DCP 3060 has a separate menu key There are 6 menus for each output channel Signal Signal parameters Refer to the Input Menus for details EQ EQ paramters Refer to the Input Menus for detail...

Page 14: ...tem Menu O1 XXXXXX XOver FRQL 1000Hz SLPL Filter Slope of low frequency crossover point high pass Ranges from 6 to 48dB octave If the selected Filter Type is Linkritz Riley the available slopes are 12...

Page 15: ...ot Off FRQL FRQH Limit Output Limter THRESH Limit Threshold Ranges from 20 to 20dBu in 0 5dB steps O1 XXXXXX Limit THRESH 20 0dB ATTACK Attack time Ranges from 0 3 to 1ms in 0 1ms steps then ranges fr...

Page 16: ...t source On or disable it Off If more than one input source are enabled they will be added together as the source for the current output channel O1 XXXXXX Source In1 On O1 XXXXXX Source In2 Off O1 XXX...

Page 17: ...lled using this menu PROG Program Number to be recalled Only first 8 characters of the program name is displayed O1 XXXXXX Recall PROG 01 XXXXXXXX Store Program store The DCP 3060 has a built in non v...

Page 18: ...gured manually in the Xover Menu in each Output menu Note The configuration mode configures the input sources when selected The user can change the source afterwards if desired It does not keep the co...

Page 19: ...ce ID from 1 to 16 This ID is useful when a network of more than 1 unit is present O1 XXXXXX Generl DEVICE 1 Security Security Lock The DCP 3060 enables the user to secure the unit and prevent undesir...

Page 20: ...r FTRL Off Butterworth Linkwitz Riley Bessel Crossover Low XOver FRQL 20 20 000 1 Hz Crossover Low XOver SLPL 6 48 6 dB octave Crossover High XOver FTRH Off Butterworth Linkwitz Riley Bessel Crossover...

Page 21: ...he DCP 3060 unit from a remote PC via the RS232 serial communication link The GUI application makes it much easier to control and monitor the device allowing the user to get the whole picture on one s...

Page 22: ...o Performance Processor 32 bit 40 bit extended Sampling Rate 48kHz Analog Converters High Performance 24 bit Propagation Delay 3ms Front Panel Controls Display 2 x 16 Character Backlit LCD Level Meter...

Page 23: ...ter Types Butterworth Bessel Linkwitz Riley Slopes 6 to 48dB oct Limiters Threshold 20 to 20dBu Attack 0 3 to 100ms Release 2 to 32X the attack time System Parameters No of Programs 30 Program Names 1...

Page 24: ...without factory authorization or by anyone other than authorized Xilica Field Service Stations This warranty is void if the serial number has been defaced altered or removed Products covered by this w...

Page 25: ...User Manual v4 01 Apr 2005 XILICA Audio Design 88 Oxford Street Richmond Hill Ontario Canada L4C 4L5 Phone 905 770 0055 Fax 905 770 2984 www xilica com...

Reviews: