XICOY V10 User Manual Download Page 7

Command 

Meaning 

Answer (Payload) 

Update 
rate 

Adapter 
version 

Fadec 
models 

RSD 

Read Screen Data 

ASCII text 32 byte 

All 

All 

RCV 

Read Current Values 

RPM, EGT in ºC, Pump Power, Voltage of Battery, Throttle % 

All 

All 

WDU 

Data Up Command 

OK.             

-> Send to the fadec a keypress on the “+” button

 

All 

All 

WDD 

Data Down Command 

OK.             

-> Send to the fadec a keypress on the “-” button

 

All 

All 

WMU 

Menu Up Command 

OK.             

-> Send to the fadec a keypress on the “^” button

 

All 

All 

WMD 

Menu Down Command 

OK.             

-> Send to the fadec a keypress on the “.” button

 

All 

All 

RAV 

Read Adapter version 

ASCII version number (ex: 1.0) 

All 

All 

REL 

Read Engine Limits 

Full Power RPM, Idle RPM, Max EGT, Pump Limit, Tank Size ml 

All 

All 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

Disposal 

Electrical equipment marked with the cancelled waste bin symbol must not be discarded in the standard household waste; instead it must be 
taken to a suitable specialist disposal system. 
In the countries of the EU (European Union) electrical equipment must not be discarded via the normal domestic refuse system (WEEE - Waste 
of Electrical and Electronic Equipment,directive 2002/96/EG). You can take unwanted equipment to your nearest local authority waste collection 
point or recycling centre. There the equipment will be disposed of correctly and at no cost to you. 
By returning your unwanted equipment you can make an important contribution to the protection of the environment. 
 
 

Summary of Contents for V10

Page 1: ...e Torrent d en Puig 31 08358 Arenys de Munt Barcelona Catalonia Spain E mail info xicoy com Fax 34 933 969 743 web www xicoy com Xicoy WEEE register number ES004749 Copyright 2014 Xicoy Electronica SL...

Page 2: ...systems like test bench setups on universities Electrical connections The adapter connects to the ecu trough the supplied 3 wire patch lead and it is powered by the ecu On the other side of the adapte...

Page 3: ...rieved from the fadec plus a couple of parameters to be programmed on the adapter This programming is only necessary if you plan to use the fuel flow and tank capacity information The programming proc...

Page 4: ...by the telemetry on landing 3 After landing before to shut down the receiver check the of remaining fuel displayed on the telemetry screen 4 Measure the real quantity of fuel left If you use a regular...

Page 5: ...ough different commands See table Note that the adapter is continuously retrieving the data from the fadec but due at the nature of the fadec protocols and speed data speed used on different fadec mod...

Page 6: ...Sync 2Ch Separator 52h R 53h S 44h D 2Ch Separator 0Dh CR last byte The ecu will return two strings First a copy of the command received followed by the data requested In the above example it will re...

Page 7: ...l REL Read Engine Limits Full Power RPM Idle RPM Max EGT Pump Limit Tank Size ml S All All Disposal Electrical equipment marked with the cancelled waste bin symbol must not be discarded in the standar...