Electric connections 

 
Connect the 3 sensors to the display unit using the leads supplied 
(

Picture 2

). Leads can be extended using standard servo leads if 

necessary.  Respect  the  proper  orientation  of  the  connector  as 
per the labels on the underside of the sensors and on the lateral 
on  the  display.  The  3  sensors  are  identical  and  interchangeable 
on the 40kg version, but on the 100kg version, it uses 2 sensors 
rated to 50Kg on the mains.

 

Connect  a  standard 

battery (not supplied) 
on  the  “Bat”  input. 
Battery voltage could be from 5V to 9V (

Picture 3

).  

Connect the  sensors  to  the  sockets  on  the  display 
unit.  Connect  the  sensor  placed  on  the  Nose 
(Tricycle  Undercarriage)  or  tail  (Bicycle/Tail 
Dragging  planes)  in  the  “Nose”  input,  and  the 
sensors  on  the  main  wheels  on  the  “Left”  and 
“Right” inputs. 
 

 

 

 

System check and calibration 

 
Before  to  measure  the  weight  or  the  CG,  it  is  important  to  check  and  calibrate  the  sensors, 
especially  if  they  have  got  mechanical  stress,  like  transport  or  shock,  if  the  temperature  is 
significantly different since last calibration, or at least once per year. 
 
After power-on, leave the system to stabilize for at least 5 minutes. Then touch the “weight” 
button,  and  next  touch  the  “Tare”  button.  All  3  readings  should  display  zero.  Then  place  a 
known weight on each scale and check that the reading is accurate and same on the 3 scales. If 
the  readings  are wrong,  then  perform  the calibration  procedure  described  in  the 

“Advanced 

Options”

 section. 

 

Measuring the weight 

 
 
Place the sensors close to the wheels of the airplane and connect 
the battery. Don’t place the wheels over to the sensors yet. 
 

Click  on  the  “Weight”  (

Picture  4

button on the main screen. 
The  individual  readings  of  the  3 
sensors  will  be  displayed,  together 
with the Total Weight (

Picture 5

). 

 
Sometimes you will see that the readings are not exactly zero. This 
is  normal;  the  sensors  could  drift  a  little  due  temperature  and 

Picture 2 

Picture 3 

Picture 4 

Picture 5 

Summary of Contents for CG Meter 1.4

Page 1: ...au 18 08360 Canet de Mar Barcelona Catalonia Spain E mail sales xicoy com 34 93 794 27 74 web www xicoy com Xicoy WEEE register number ES004749 DE 36558999 Copyright 2015 Xicoy Electronica SL All Rights Reserved Manual contents design Gaspar Espiell V1 4 ...

Page 2: ...b weight standard model or up to 100Kg 220lb on the HD model By replacing the weight sensor by angle sensors the system can be used to adjust the travel of control surfaces and to measure the different relevant angles in an aero plane The display unit can store the settings of up to 100 different models and can save recover the data on a uSD card not supplied Measuring CG and Weight The system con...

Page 3: ...ortant to check and calibrate the sensors especially if they have got mechanical stress like transport or shock if the temperature is significantly different since last calibration or at least once per year After power on leave the system to stabilize for at least 5 minutes Then touch the weight button and next touch the Tare button All 3 readings should display zero Then place a known weight on e...

Page 4: ...se measures are 1 Distance between the center of the sensors under the main wheels and the center of sensor under the nose wheel 2 Distance between the center of the sensors under the main wheels and the desired position of the CG 3 Distance between the center of the sensors under the main wheels and the place where the correction weight will be added removed Distances 1 and 2 should be measured a...

Page 5: ...ess to the measured results Depending of the model type selected the displayed image will be different but the data is the same On top left side the model name is shown On top of the drawing the distances set in the setup screen are shown The CG symbol is placed on the drawing at scale distance and the correction point is shown as a BLUE dot Under the drawing the results of the measure are shown T...

Page 6: ...sitions marked in BLUE lines The current position line is YELLOW in color when the position of the surface is between minimum and maximum Picture 12 The color will change to GREEN when the deflection is exactly as desired 0 5º If the deflection is excessive then the line color changes to RED Entering the data of the surfaces The unit accepts the data in either Distance or in Degrees Usually the ma...

Page 7: ...e accordingly its position turning to GREEN in color when in correct position at full deflection The Side Buttons allow selecting the reference for the measurements Five options are offered Picture 17 1 Ground Absolute The 3 sensors work independently and the zero is absolute factory calibrated like a bubble level zero degrees will be displayed when the sensor is absolutely parallel to ground 2 Gr...

Page 8: ...ration this button provides access to the calibration procedure CAUTION The calibration data from factory will be lost Picture 19 Do not calibrate a sensor if you don t have a precision reference weight of at least 1kg The sensors store the calibration values in the sensor memory In order to have access to this memory by the display module the sensor to be calibrated should be connected to input 1...

Page 9: ... instead it must be taken to a suitable specialist disposal system In the countries of the EU European Union electrical equipment must not be discarded via the normal domestic refuse system WEEE Waste of Electrical and Electronic Equipment directive 2002 96 EG You can take unwanted equipment to your nearest local authority waste collection point or recycling centre There the equipment will be disp...

Reviews: