XIA FalconX1 Quick Start Manual Download Page 4

FalconX1/X4/X8 Quick Start Guide 

 

Version 0.6 

 

August 23, 2019 

 

 

Connect an Ethernet cable (capable of supporting 1 Gbps) to the standard RJ45 
connector. See below for more detail on the network setup. 

 

Connect the detector preamplifier outputs to the input SMA connectors. Short SMA 
to BNC cables (provided) can be used if conversion is necessary. 

 

To turn on the box, press the button on the front panel, which will turn blue to 
indicate that power is on. If the button turns red, it indicates a power fault. 

 

To turn the unit off, press and hold the power button for more than three seconds. 

1.2  Network Setup 

 

We strongly recommend using a gigabit Ethernet network to connect the FalconXn to 
the  host  computer  systems.  For  best  results  with  fast  mapping  applications  (which 
involve  very  high  data  transfer  loads),  it  is  best  to  use  a  dedicated  network 
connection, so that the full data bandwidth is available to carry the high data load. 

The  FalconXn  can  be  setup  to  use  either  DHCP  to  obtain  its  IP  address,  or  with  a 
static  address  for  situations  where  a  DHCP  server  is  not  available.  The  network 
settings  can  be  modified  either  through  the  web  server  (see  below)  or  through  a 
service port on the instrument (which is beyond the scope of this document). 

Please note that units are shipped with a static ip address set to 192.168.0.2. To make 
the  initial  connection  to  the  FalconXn,  it  is  typically  easiest  to  make  a  direct 
connection to the host computer; in this setup, the host computer will also need to be 
set to a fixed ip address on the same subnet as the FalconXn (such as 192.168.0.1). 

1.3  Web Server 

To get started, it is best to make the initial connection through the built-in web server on the FalconXn. 
To access the web server, just type the ip address of the box into the browser address on a computer that 
is connected to the same Ethernet subnetwork as the box. Upon first connection, you will be prompted for 
login credentials: username: 

user

, password 

password

. The web server has several panels, described 

below, which are selected using the tabs along the top of the page. 

1.3.1  Status 

Summary of Contents for FalconX1

Page 1: ...com Information furnished by XIA LLC is believed to be accurate and reliable However no responsibility is assumed by XIA for its use or for any infringements of patents or other rights of third partie...

Page 2: ...e Setup 3 1 2 Network Setup 4 1 3 Web Server 4 1 3 1 Status 4 1 3 2 Firmware 5 1 3 3 Config 6 1 3 4 Log 6 1 3 5 Reset 7 2 ProSpect Control of the FalconXn 8 2 1 Configuration File 8 2 2 Analog Setup a...

Page 3: ...data acquisition features such as fast mapping and list mode output 1 1 Hardware Setup The FalconX1 X4 X8 processors are packaged in an a compact aluminum chassis which can easily be located close to...

Page 4: ...n be setup to use either DHCP to obtain its IP address or with a static address for situations where a DHCP server is not available The network settings can be modified either through the web server s...

Page 5: ...the board is indicated by the color of the tab at the top where red or orange will indicate an alarm or error state 1 3 2 Firmware The firmware tab shows what firmware versions are installed and allo...

Page 6: ...tion settings Pressing the edit saved config button allows the user to change the network settings from dhcp to static ip for example 1 3 4 Log The log tab shows basic information from the initial sta...

Page 7: ...FalconX1 X4 X8 Quick Start Guide Version 0 6 August 23 2019 7 1 3 5 Reset The Reset tab allows the user to reboot the FalconXn unit in order to restore to initial conditions...

Page 8: ...els specified for the module Note that it is possible to make a setup for a number of channels that differs from the number of channels of the target unit if you only want to use a subset of the chann...

Page 9: ...g settings have been adjusted the next step is to characterize the pulse or measure the shape of the pulse it is necessary to have this characteristic pulse shape prior to collecting MCA data the MCA...

Page 10: ...e MCA data To get started switch to the main MCA panel and also select the Acquisition tab on the left see screenshot below In the Acquisition tab you can select the number of bins in the spectrum up...

Page 11: ...eup inspection at the expense of some resolution at low rates Please note that this setting shoul only be used with very short rise times resolution performance is significantly degraded using this fi...

Page 12: ...ne an ROI in the MCA window around the target energy range then transfer that ROI definition to the FalconXn unit using the appropriate buttons on the SCA panel You can control the width of the pulses...

Page 13: ...August 23 2019 13 2 6 ProSpect For more details concerning the use of ProSpect please consult the User Manual for the DXP Mercury as the common features of the ProSpect interface are described there a...

Reviews: