![xFusion Digital Technologies FusionServer G5500 V7 Technology White Paper Download Page 22](http://html2.mh-extra.com/html/xfusion-digital-technologies/fusionserver-g5500-v7/fusionserver-g5500-v7_technology-white-paper_5005726022.webp)
Silkscreen
Indicators
and Buttons
Description
FlexIO card
presence
indicator
Indicates whether the FlexIO card is detected.
● Off: The OCP 3.0 NIC is not in position.
● Blinking green at 0.5 Hz: The OCP 3.0 NIC is
in position but is not powered on.
● Blinking green at 2 Hz: The OCP 3.0 NIC is in
position and has just been inserted.
● Steady green: The OCP 3.0 NIC is in
position, and the power supply is normal.
iBMC direct
connect
management
port indicator
Indicates the status when the iBMC direct
connect management port connects to a
terminal (local PC or Android mobile phone):
● Off: No terminal is connected.
● Blinking green at short intervals for 3 seconds
and then off: The port is disabled.
● Steady green: The terminal is connected.
Indicates the status when the iBMC direct
connect management port connects to a USB
device:
● Blinking red at long intervals: The job fails or
an error is reported when the job is complete.
● Blinking green at short intervals: The job is
being executed.
● Blinking green at short intervals for 3 seconds
and then off: The port is disabled.
● Steady green: The server configuration file is
being copied from the USB device or the job
is successfully completed.
5.1.3 Ports
Port Positions
●
24 x 3.5" drive configuration
FusionServer G5500 V7 Server
Technical White Paper
5 Hardware Description
Issue 02 (2023-12-13)
Copyright © xFusion Digital Technologies Co., Ltd.
15