![xFusion Digital Technologies FusionServer G5500 V7 Technology White Paper Download Page 10](http://html2.mh-extra.com/html/xfusion-digital-technologies/fusionserver-g5500-v7/fusionserver-g5500-v7_technology-white-paper_5005726010.webp)
●
The RAID controller card supports Intel VROC (VMD NVMe RAID) for RAID
management of NVMe drives. Different VROC keys can be configured to support
multiple RAID levels.
●
The server provides simplified O&M and efficient troubleshooting through the
UID/HLY indicators on the front panel, fault diagnosis LED, and iBMC WebUI.
●
The panel provides the iBMC direct connect management port to support local
iBMC O&M, improving O&M efficiency.
●
The server provides four hot-swappable PSUs in 2+2 or 3+1 redundancy mode
and six or eight hot-swappable fan modules in N+1 redundancy mode, improving
system availability.
●
The onboard Intelligent Baseboard Management Controller (iBMC) can
continuously monitor system parameters, trigger alarms, and take recovery
measures to minimize shutdown.
●
For more information about the warranty in the Chinese market, see
.
Manageability and Security
●
The built-in iBMC monitors system operating status and provides remote
management.
●
A password is required for accessing the BIOS, ensuring system boot and
management security.
●
The Network Controller Sideband Interface (NC-SI) feature allows a network port
to simultaneously serve as a management port and a service port. The NC-SI
feature is disabled by default and can be enabled or disabled on the iBMC or
BIOS.
NO TE
The service port with NC-SI enabled supports the following configuration:
● Configuring any network port on the OCP 3.0 NIC or PCIe NIC (with NC-SI enabled).
● If the standard PCIe card supports the NC-SI function, it can be installed in slot 18
only.
● Enabling, disabling, and setting a virtual local area network (VLAN) ID for this port.
The VLAN ID is
0
and disabled by default.
● Configuring IPv4 addresses (IPv4 address, subnet mask, and default gateway) and
IPv6 addresses (IPv6 address, prefix length) for this port.
●
The integrated Unified Extensible Firmware Interface (UEFI) improves setup,
configuration, and update efficiency and simplifies fault clearance.
●
The lockable server chassis panel ensures local data security.
●
Chassis cover opening detection is supported to enhance physical security.
●
Intel Execute Disable Bit (EDB) function prevents certain types of malicious
buffer overflow attacks when working with a supported OS.
●
Intel
®
Trusted Execution Technology prevents malicious software attacks based
on hardware, prevents the firmware on the device from being maliciously
modified, and prevents unauthorized boot block execution.
●
Intel
®
Software Guard Extensions (SGX) technology allows applications to run in
their own independent space without being affected by other software running in
the system, thereby enhancing security.
FusionServer G5500 V7 Server
Technical White Paper
2 Features
Issue 02 (2023-12-13)
Copyright © xFusion Digital Technologies Co., Ltd.
3