![xFusion Digital Technologies FusionServer 1288H V5 Technical Paper Download Page 9](http://html1.mh-extra.com/html/xfusion-digital-technologies/fusionserver-1288h-v5/fusionserver-1288h-v5_technical-paper_3317192009.webp)
FusionServer 1288H V5 Server
Technical White Paper
2 Features
2023-02-28
9
⚫
The use of all solid-state drives (SSDs) is supported. An SSD supports up to 100
times more I/O operations per second (IOPS) than a typical hard disk drive (HDD).
The use of all SSDs provides higher I/O performance than the use of all HDDs or
a combination of HDDs and SSDs.
⚫
The LANs on motherboard (LOMs) and FlexIO cards provide a variety of ports to
meet different networking requirements.
⚫
With Intel integrated I/O, the Intel
®
Xeon
®
Scalable processors integrate the PCIe
3.0 controller to shortens I/O latency and improve overall system performance.
⚫
The server supports up to three PCIe 3.0 slots.
Availability and Serviceability
⚫
Carrier-class components with process expertise ensure high system reliability
and availability.
⚫
The server uses hot-swappable SAS/SATA/NVMe drives. It supports RAID 0, 1,
1E, 10, 5, 50, 6, and 60, depending on the RAID controller card used. It also uses
a supercapacitor to protect the RAID cache data against power failures.
⚫
The SSDs offer better reliability than HDDs, ensuring continued system
performance.
⚫
The server provides simplified O&M and efficient troubleshooting through the
UID/HLY LED indicators on the front panel, fault diagnosis LED, and iBMC
WebUI.
⚫
The iBMC monitors system parameters in real time, triggers alarms, and
performs recovery actions in case of failures, minimizing system downtime.
⚫
For more information about the warranty in the Chinese market, see
Manageability and Security
⚫
The built-in iBMC monitors server operating status and provides remote
management.
⚫
A password is required for accessing the BIOS, ensuring system boot and
management security.
⚫
The Network Controller Sideband Interface (NC-SI) allows a network port to
serve as a management port and a service port for maximized return on
investment (ROI) for customers. The NC-SI feature is disabled by default and can
be enabled through the iBMC or BIOS.
⚫
The integrated Unified Extensible Firmware Interface (UEFI) improves setup,
configuration, and update efficiency and simplifies fault handling.
⚫
Lockable server chassis panel ensures security of local data and supports
checking upon opening the cover.
⚫
The Advanced Encryption Standard
–New Instruction (AES NI) algorithm allows
faster and stronger encryption.
⚫
Intel Execute Disable Bit (EDB) function prevents certain types of malicious buffer
overflow attacks when working with a supported OS.
⚫
Intel Trusted Execution Technology enhances security using hardware-based
defense against malicious software attacks, allowing applications to run
independently.
⚫
The trusted platform module (TPM) and trusted cryptography module (TCM)
provide advanced encryption functions, such as digital signatures and remote
authentication.