![xFusion Digital Technologies 02313LSK Manual Download Page 70](http://html1.mh-extra.com/html/xfusion-digital-technologies/02313lsk/02313lsk_manual_886219070.webp)
FusionServer 5288 V6 Server
Technical White Paper
5 Hardware Description
2022-06-25
70
Drive No.
Drive Number Identified
by the iBMC
Drive Number Identified
by the RAID Controller
46
46
-
47
47
-
5.5.3 Drive Indicators
SAS/SATA Drive Indicators
Figure 5-28
SAS/SATA drive indicators
Table 5-16
SAS/SATA drive indicators
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Off
Off
The drive is not in position.
Steady on
Off
The drive is detected.
Blinking at 4 Hz
Off
Data is being read or written properly, or
data on the primary drive is being rebuilt.
Steady on
Blinking at 1 Hz
The drive is being located.
Blinking at 1 Hz
Blinking at 1 Hz
Data on the secondary drive is being rebuilt.
Off
Steady on
A drive in a RAID array is removed.
Steady on
Steady on
The drive is faulty.