4 Modem Recovery
The COM1 serial port of the radio may be connected to a computer so that during
power up the current IP and MAC address of the Ethernet board can be monitored.
At power up, COM1 uses these settings: 19200 baud, 8N1, no flow control.
In addition to showing current configuration settings, a user can reset the radio to
factory default settings. To reset the radio to factory default settings, you must
interrupt the terminal server start up sequence by entering these commands within ten
seconds of power up:
1.
“Ctrl + R” to interrupt terminal server start up sequence.
2.
“1” to select “Restore factory settings”.
3.
“Y” to confirm that you wish to restore factory default settings, or enter any
other character to cancel.
Once “Restore factory settings” is confirmed, the device automatically restarts. If
cancelled, or if the terminal server start up sequence is not interrupted, the terminal
servers automatically start after ten seconds.
To disable VLAN mode from COM1, you must interrupt the terminal server start up
sequence by entering these commands within ten seconds of power up:
1.
“Ctrl + R” to interrupt terminal server start up sequence.
2.
“2” to select “Disable VLAN mode”.
If selected, this command disables VLAN mode, and resets the device.
Recovery