WorkCentre 7220-7225 Information Assurance Disclosure Paper
Ver. 1.0, January 2013
Page
50 of 61
4.7.3.
Overwrite Timing
The ODIO overwrite time is dependent on the type of hard disk in the product. The overwrite times are generally 20
minutes for a Standard ODIO and 60 minutes for a Full ODIO.
IIO is performed as a background operation, with no user-perceivable reduction in copy, print or scan performance.
4.7.4.
Overwrite Completion Reporting
Immediate Image Overwrite
When an Immediate Image Overwrite is performed at the completion of each job, the user may view the Completed
Jobs Log at the Local UI. In each Job entry there will be an indication if the Job was successfully overwritten or not.
On Demand Image Overwrite
Upon completion, from the Local UI an entry is made in the Audit Log at the device.
This Log may be downloaded
by the “admin” user or any user assigned an admin role. The admin may configure whether or not a Confirmation
Report will print through the CentreWare Web Ui on the Properties tab, under Security. The options are On, Errors