7.3.3 Not function of the gear of the fuser due to melting away
• Description
The motor breaks away from its place due to gear melting away.
Check and Cause
Solution
1. Check the Heat Lamp.
1. Replace the Fuser.
2. Replace the Main PBA.
2. Replace the SMPS.
7.3.4 Paper Empty
• Description
The paper lamp on the operator panel is on even when paper is loaded in the cassette.
Check and Cause
Solution
1. Bending or deformation of the actuator of the paper sen-
sor.
2. The function of the engine board is defective
3. Check the Connector.
1. Replace the defective actuator.
2. Replace the Sensor PBA.
Summary of Contents for Phaser 3450