Page 2-36
Xerox WorkCentre 450c/450cp Service Manual
RAP 7.2: Control Panel LCD
Panel
See Parts List 4.1.
This RAP will isolate an LCD problem to
the failed component.
1. Power on the unit.
2. Check the voltage between pin 1 (+5
VDC) and pin 2 (GND) on CIS Relay
board connector J4.
Result: Voltage is between 4.75
VDC and 5.25 VDC?
No:
DC Voltage Check on page 2-12.
Yes:
Continue with Step 3.
Pin 1 - Connector J4
3. In the Service Menu, perform the LCD test.
Result:Test passes?
No:
Replace the LCD circuit board
(REP 3.1.3: LCD Display on page 4-29).
If this does not fix the problem, replace the
main circuit board (REP 5.1.2: Main Board on page 4-39).
Yes:
End of RAP.
www.printcopy.info