Color Calibration
If you have specified multiple clicks per patch, continue pressing Measure to take the
required number of measurements. We recommend that you move the ES-1000 or
ED-100 slightly after each measurement while keeping it within the patch circle.
When the patch has been measured successfully, a checkmark appears in the patch
preview in the Measurements window. The window identifies and highlights the next
patch to be measured.
10.
to measure each successive patch on the Measurement Page.
To retake a measurement, first select the desired patch preview in the Measurements
window. Then measure the patch on the page using the ES-1000 or ED-100.
N
OTE
:
You must take the measurements in the order outlined in the Measurements
window and on the measurement page.
11.
When all the patches have been read successfully, click Accept.
12.
Click Apply in the Calibrator window to implement the new calibration set.
13.
Click OK in the Information dialog box.
This completes the Fiery calibration process.