![Xerox 4595 Customer Expectation Document Download Page 18](http://html2.mh-extra.com/html/xerox/4595/4595_customer-expectation-document_3331544018.webp)
Optional Oversized High Capacity Feeder (OHCF)
Section Specification
Nominal Voltage
100-240 VAC, single phase (+6% to -10%)
Amperage
15
Cycles (single phase)
50/60 HZ
Xerox Receptacle Part No.
600S3704
Receptacle NEMA Part No.
5-15R
Power Cord Length
10 feet/3 meters
Receptacle Diagram
(XNAonly, All others: Flying leads)
Power
60 W maximum
NOTE: Surge protection for the OHCF is strongly recommended and is the responsibility of the
customer.
The following illustration shows the space requirements and service space envelope for the Xerox
4595 with the optional Finisher/Folder and OHCF installed. For other configurations, consult the
Module Dimensions chart.
Note 1: The dimensions shown are absolute minimums.
Note 2: 78" (1981 mm) minimum height clearance in service envelope.
Note 3: Location of left rear corner of main processor should be marked with tape for delivery personnel.
(See diagram above)
Note 4: If there is no HCF or OHCF attached, then the Multi-Sheet Inserter, in the closed position (3.3”/83
mm), must be calculated in the space requirements.
Service/ Operational Space
Moveable Installation
1
Stationary Installation
Rear of Main Processor/System
10”/254 mm
24”/610 mm
Front of Main Processor
54”/1372 mm
54”/1372 mm
Front of HCF and Finisher/Folder
38”/965 mm
38”/965 mm
Front of OHCF and Finisher/ Folder
38”/965 mm
38”/965 mm
Side of System
24”/610 mm
24”/610 mm
Height of System
78”/1981 mm
78”/1981 mm
1
Moveable installation dimensions can be used when the system is installed on a hard surface
(concrete, wood, and/or with a mobility plate).
18