Xenteq PTS 230-20 User Manual Download Page 7

 

 

EN 

Attention:

  for  230VAC  equipment  you  do  not  want  to  operate  via  the 

inverter, such as a battery charger, a separate circuit must be made. So if 

you connect the entire 230VAC circuit to the switch box, all equipment will 

automatically be switched to the 230VAC output of the inverter. 

 

Mounting 

1.

 

Open the housing by removing the screws on the top. 

2.

 

On  the  4  corners,  you  can  install  the  accompanying  screws  into  the 

holes in the housing. In this way, the housing can be mounted on a flat 

surface. 

 

Connection 

1.

 

Run the power cable from the mains input through the right swivel and 

connect it to the 3 screw connectors on the PCB (MAINS INPUT). Refer 

to the drawing. 

2.

 

Run  the  power  cable  for  the  output  /  consumers  through  the  middle 

swivel  and  connect  it  to  the  3  corresponding  screw  connectors  on  the 

PCB (OUTPUT). Refer to the drawing.  

3.

 

Tighten all swivels properly. 

4.

 

Close the housing again. Press the included corner pieces on to the four 

corners of the housing. 

5.

 

Connect the power cord with plug (INVERTER INPUT) to the output of 

the inverter/generator. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L=

 

phase (brown)   

N= 

 

neutral (blue)  

PE=   ground (green-   

                    yellow) 

       OUTPUT         MAINS INPUT 

  

L       N     PE       PE     N     L 

INVERTER 

INPUT 

Inverter/

     

   Output            Mains 

generator   

Summary of Contents for PTS 230-20

Page 1: ...PTS serie Gebruiksaanwijzing P a g i n a 2 Users manual Pa g e 6 Gebrauchsanweisung S e i t e 9 NL EN DE POWER TRANSFER SWITCH...

Page 2: ...zodat het geen invloed heeft op de verbruikers Dit maakt de PTS ook geschikt voor plaatsing in een back up systeem De PTS is voor meerdere combinaties van 230VAC circuits geschikt Dit kan dus zijn net...

Page 3: ...el van het verwijderen van de schroeven aan de bovenzijde 2 Op de 4 hoeken kunt u de meegeleverde schroeven in de daarvoor bestemde gaten in de behuizing plaatsen Op deze wijze kan de behuizing gemont...

Page 4: ...akelen De uitgang is beveiligd door middel van een zekering Deze is gemakkelijk zelf te vervangen via de van buitenaf te bereiken zekeringhouder Plaats altijd een zekering terug met gelijke waarde Bel...

Page 5: ...ient gefrankeerd op gestuurd te worden Op alle modellen uit de PTS serie wordt twee jaar garantie verleend vanaf verkoopdatum en alleen op de onderdelen en arbeidsloon van de reparatie Garantieduur is...

Page 6: ...tage in combination with DC AC inverter mains voltage in combination with generator generator in combination with DC AC inverter INSTALLATION Important Make sure the system is completely voltage free...

Page 7: ...face Connection 1 Run the power cable from the mains input through the right swivel and connect it to the 3 screw connectors on the PCB MAINS INPUT Refer to the drawing 2 Run the power cable for the o...

Page 8: ...fore sending back the device always advice all information in this manual first In case of a malfunction the device can be send to us directly or you can choose to arrange the return with your dealer...

Page 9: ...re Kombinationen von 230V Wechselstromkreisen Das kann beispielsweise sein Netzspannung in Verbindung mit Wechselrichter Netzspannung in Verbindung mit Aggregat Aggregat in Verbindung mit Wechselricht...

Page 10: ...ntfernen 2 An den 4 Ecken k nnen Sie die mitgelieferten Schrauben in die daf r vorgesehenen L cher im Geh use anzubringen Auf diese Weise kann das Geh use auf einem ebenen Boden befestigt werden Ansch...

Page 11: ...er Ausgang wird mit einer Sicherung gesichert Diese kann durch den leicht von au en erreichbaren Sicherungshalter einfach selbst ersetzt werden Setzen Sie immer eine Sicherung mit dem gleichen Wert ei...

Page 12: ...en Das Ger t muss frankiert versendet werden Auf die PTS Serie wird eine Garantie von 2 Jahren ab dem Verkaufsdatum gew hrt Der Garantieumfang umfasst dabei nur die Ersatzteile und den Arbeitslohn der...

Page 13: ...13...

Page 14: ...14 Xenteq BV Banmolen 14 5768 ET Meijel Nederland Tel 31 0 77 4662067 Fax 31 0 77 4662845 info xenteq nl www xenteq nl V1C...