![Xenteq PPI 1000-212CP User Manual Download Page 14](http://html.mh-extra.com/html/xenteq/ppi-1000-212cp/ppi-1000-212cp_user-manual_882645014.webp)
14
E N
N L
Short-circuit on the output
The inverter will switch off the 230VAC output voltage if there is a short-circuit of
the output. During this protection, the red ‘fault’ led will flash slowly. The inverter
will restart automatically, once the problem has been resolved.
Overload
protection
The inverter will shut down the 230VAC output if the requested power on the
output is higher than the continuous power of the inverter. The red ‘fault’ indicator
will flash slowly. The inverter will restart automatically, once the problem has been
resolved.
Important
The overload protection only works with the maximum power and not with the
surge power. If the surge power of the inverter is exceeded then the inverter will
break! In this case the repair costs are not covered by warranty.
T H E P U R E P O W E R A P P
An app is available for the PurePower PLUS inverter models
called 'PurePower app'. This can be downloaded for free in the
Google Play Store and the Apple Store. With this app it is
possible to adjust the factory settings such as: undervoltage
level, overvoltage level, power save mode, etc. Furthermore, the
clear dashboard shows, among other things, the output power,
the input voltage and the report any errors. The language of the
app is customizable. For further explanation and method of the
app, please refer to our website www.xenteq.nl
I N S T A L L A T I O N
Mounting
The inverter must be mounted in a space that complies with the following:
-
Mount the inverter in a dry place where there is no chance of it being affected
by moisture or dirt. Also be aware of moisture or dirt that can be sucked in by
the fan.
-
In a room with high humidity, there is a high risk of condensation in the device.
This can cause moisture damage.
-
Ideal ambient temperature is between 15 C and 25 ºC.
-
Leave enough space on all sides of the inverter (min. 10cm) for air circulation.
Make sure that there are ventilation vents.
-
Keep the inverter out of the reach of children.
-
A working inverter produces a dangerous voltage.
-
Do not use the inverter in places where gases are released or flammable
materials are stored.