PAGE 7
9. HEAD SAFETY CIRCUIT FAULT INDICATOR.
THIS INDICATOR LIGHTS INDICATING A TROUBLE CONDITION IN THE LAMP HEAD. UNDER NORMAL OPERATING
CONDITIONS THIS INDICATOR WILL LIGHT FOR A FEW SECONDS WHEN THE SYSTEM IS FIRST ENERGIZED UNTIL
PRESSURE BUILDS UP IN THE LAMP HEAD COOLING SYSTEM. THIS INDICATOR WILL LIGHT IF THE FOLLOWING
FAULT CONDITIONS EXIST IN THE LAMP HEAD SECTION OF THE SYSTEM. OVER TEMPERATURE, COOLING
BLOWER FAILURE, INSUFFICIENT AIRFLOW WITHIN THE COOLING SYSTEM. WHEN THE PROBLEM IS CORRECTED
THIS INDICATOR WILL EXTINGUISH AND THE SYSTEM WILL GO INTO NORMAL OPERATION.
NOTE
IF A FAULT CONDITION EXISTS IN BOTH THE LAMP HEAD AND BALLAST UNITS ( SUCH AS A TRIPPED PHASE LOSS
CIRCUIT BREAKER AND A NON OPERATING LAMP HEAD COOLING SYSTEM ) BOTH INDICATOR WILL LIGHT
DIMLY.
10. BALLAST CURRENT OUTPUT TEST POINTS
USED TO MONITOR THE BALLAST OUTPUT CURRENT DURING THE POWER OUTPUT ADJUSTMENT PROCEDURE.
OUTPUT RANGE 0 - 50 MILLIVOLTS DC = (0 - 300 AMPS DC).
11. BALLAST CURRENT OUTPUT METER
USED TO MONITOR THE BALLAST OUTPUT CURRENT DURING THE POWER OUTPUT ADJUSTMENT PROCEDURE.
12. VOLT METER DISPLAY SWITCH
THIS SWITCH MUST BE PRESSED TO VIEW THE BALLAST OUTPUT VOLTAGE WHILE THE LAMP IS OPERATING.
CAUTION
PRESSING THIS SWITCH WHILE THE BALLAST IS IN PRE IGNITION MODE (BOOST MODE) MAY DAMAGE THE VOLT
METER.
13. BALLAST VOLTAGE OUTPUT TEST POINTS
USED TO MONITOR THE BALLAST OUTPUT VOLTAGE DURING THE POWER OUTPUT ADJUSTMENT PROCEDURE.
OUTPUT RANGE 0 - 140 VDC.
14. BALLAST VOLTAGE METER
USED TO MONITOR THE BALLAST OUTPUT VOLTAGE DURING THE POWER OUTPUT ADJUSTMENT PROCEDURE.
15. BALLAST OUTPUT FINE ADJUSTMENT SWITCH
USED TO ADJUST THE BALLAST OUTPUT DURING THE POWER OUTPUT ADJUSTMENT PROCEDURE.
16. BALLAST OUTPUTCOARSE ADJUSTMENT SWITCH
USED TO ADJUST THE BALLAST OUTPUT DURING THE POWER OUTPUT ADJUSTMENT PROCEDURE.
LAMP HEAD
1. FOCUS SWITCH
LOCATED ON THE REAR OF THE LAMP HEAD THIS SWITCH IS USED TO FOCUS THE SEARCHLIGHTS BEAM
ANGLE. MOVING THE SWITCH TO THE UPPER OR LOWER POSITION STARTS THE MOTOR THAT ADJUSTS THE
LAMP. MOVING THE SWITCH TO THE OPPOSITE POSITION REVERSES THE MOVEMENT.
NOTE
THE TWO PUSH BUTTON SWITCHES TO THE RIGHT OF THE FOCUS SWITCH ARE REMOTE LAMP STRIKE AND OFF
SWITCHES AND ARE NOT USED ON SYSTEMS ARCHITECTURAL SYSTEMS INCORPORATING AUTOMATIC
IGNITION CIRCUITRY. PRESSING THE OFF SWITCH WHILE THE LAMP IS LIT WILL CAUSE THE LIGHT TO
EXTINGUISH MOMENTARILY UNTIL THE AUTO IGNITION RESTARTS THE LAMP. PRESSING THE ON BUTTON WILL
ENERGIZE THE IGNITOR CIRCUIT. THIS FUNCTION IS THE SAME AS THE MANUAL STRIKE SWITCH LOCATED ON
THE BALLAST CONTROL PANEL AND MAY BE USED TO TEST A SYSTEM THAT DOES NOT AUTOSTRIKE.