Xenosys XD LIGHT User Manual Download Page 6

 

Portable  LED  HeadLight  System  (XD Light)                                                                                                  www.xenosys.co.kr 

 

1. The battery is lithium-ion rechargeable one. 

2.  When  transporting  only  battery,  make  sure  to  keep  it  in  soft  case.  Do  not  make  any 

conductor to connect the battery charging point. 

3.  The  battery  operating  time  may  shorten  using  in  the  cold  place  (below  (-10℃)  even  fully 

charged one.  In that case,  warm up  the battery  within  the pocket before using  L2S15.  Do 

not heat up the battery with microwave or any heater. 

4. Use only the charger which is provided by Xenosys. 

5. Charger battery in the range of +10℃  ~ +35℃. It may take longer to charger the battery out 

of this temperature range. 

6.  Provided  battery  can  be  charged  and  discharged  about  300  times  at  room  temperature. 

Lithium-ion battery is expendables, thus if the operating time is shortened after full charge, 

we recommend exchanging new battery.   

7.  Be  careful  on  benzene,  thinner,  alcohol  (volatile  &  flammable  fluid)  and  water.  If  those 

chemicals penetrate the battery, it may cause the trouble in circuit and any accident. 

8.  If  there  is  any  swollen  battery,  spill,  emit,  or  fire,  stop  using  immediately  and  contact  the 

distributor (dealer) or the manufacturer. 

9. Never use any damaged battery and charger. 

10.  In  case  of  the  first  installation  or  unused  long  time,  then  charge  the  battery  fully  before 

using. 

 

  WARNING for Charger: 

1.  Do  not  connect  any  metallic  objects  between  the  cradle  connector  and  battery.  This  may 

cause the defective on the charger and charger cradle.   

2. Use only the charger which is provided by Xenosys on the phone jack. This may cause the 

defective on the charger and charger cradle. 

  WARNING for Disposal: 

1.

 

In  case  of  careless  disposal,  it  may  pollute  the  environment,  so  make  sure  to  separate 

collection. 

 

Summary of Contents for XD LIGHT

Page 1: ...dLight System User Manual Optical Device Medical Device System Engineering XENOSYS CO LTD 2 Venture ro 100 beon gil Yeonsu gu 22013 Republic Korea TEL 82 32 875 9811 2 FAX 82 32 875 9813 www xenosys c...

Page 2: ...ble of Contents INTRODUCTION 3 SAFETY PRECAUTIONS 4 FEATURES 7 COMPONENTS 8 FUNCTIONS 9 OPERATING INSTRUCTION 11 BASIC TROUBLESHOOTING 16 SPECIFICATIONS 17 ELECTROMAGNETIC COMPATIBILITY 19 TRANSPORTAT...

Page 3: ...This product is the medical device and KFDA approval registration is described like below table Registration No 1909 Certificate No Gyeongin Jesin 07 86 Product Category I A General Instruments Class...

Page 4: ...esence of a flammable anesthetic mixture with air oxygen or nitrous oxide WARNING for Power Unit 1 Do not use any undesignated charger by Xenosys If any damage or unexpected hazard happens by the usag...

Page 5: ...ergent or chemical fluid to clean which may cause discoloration 8 Avoid the reach of children or pets 9 Maintain the following conditions for storing the product Environment for Storage Transportation...

Page 6: ...if the operating time is shortened after full charge we recommend exchanging new battery 7 Be careful on benzene thinner alcohol volatile flammable fluid and water If those chemicals penetrate the ba...

Page 7: ...ing 1 Battery Pack Imbedded DC3 62V 2950mAh Lithium Ion 2 Charger Input DC5V 2000mA Output DC4 2V 1500mA 3 Medical power supply Input AC100 240V 50 60Hz 0 3A Output DC5V 2000mA 3 Protection Classifica...

Page 8: ...xenosys co kr 8 COMPONENTS 1 Basic Components Control Unit DCU LED Lens Module DLM82 Medical Power Supply BPM010S05 Power Cord LPC Gown Clip GOC Screw driver Universal Clip 2 Optional Dental Anti curi...

Page 9: ...ower Supply BPM010S05 Refer to page 10 1 Power Cord LPC 1 Gown Clip GOC 1 Screw driver Universal Clip 1 Anti curing Filter LF0882 Dental Anti curing Filter For DLM82 1 Optional LED Lens Module DLM150...

Page 10: ...ble link LED Lens module can move up down and left right side Warning Do not use non Xenosys supplied power supply This will cause severe damage to the cradle main body which is also excluded from the...

Page 11: ...trol unit fully charged battery then connect LED lens module wire to the circular connector of the control unit B Operating Instructions 1 Finish the preparation and put the main body to waist belt or...

Page 12: ...ater or electrolyte flow into the main body 6 In case of malfunctioning stop using immediately and contact the dealer 7 Do not disassemble repair or modify the equipment by unauthorized personnel Caut...

Page 13: ...ep sound the power will shut down after 10 minutes Caution Please recharge when hearing beep sound and only a few moments light come which means the battery is not charged 2 Press the intensity change...

Page 14: ...ctor to control unit make XENOSYS logo facing in front and connect to the phone jack of control unit Prepare to connect After connected 2 How to disconnect Grab the metal part of LED lens module and r...

Page 15: ...ortable LED HeadLight System XD Light www xenosys co kr 15 F LED Lens Module attachment examples Rigid Headband TTL Loupe of Xenosys Flip up Loupe of Xenosys Normal glasses Protective goggle of Xenosy...

Page 16: ...ain Light comes on a few moments and turn off Check the battery remaining quantity Recharge the battery The light intensity is not enough Check the intensity is properly adjusted Adjust the intensity...

Page 17: ...Light System XD Light www xenosys co kr 17 SPECIFICATIONS 1 Measurement Weight A Control Unit DCU Size Refer to below photo Weight 105 g B LED Lens Module DLM82 Size Refer to below photo Weight 57 g 1...

Page 18: ...ation Electrical Specification Operating Power DC3 62V 550mA Operating Time About 22 hours 1st step mode Minimum About 11 hours 2nd step mode About 7 5 hours 3rd step mode About 5 5 hours 4th step mod...

Page 19: ...ty It is designed to protect the medical equipment from the harmful interruption This system occur electromagnetic interruption within the acceptable range And if it is not installed nor used properly...

Page 20: ...ght by hand hold it with two hands firmly and disconnect charger and power cord from the main body for safe transportation STORAGE 1 Maintain the following conditions for storing main products compone...

Page 21: ...t regularly to remove dirt and leave it dry for usage 2 Do not use volatile chemicals like benzene alcohol thinner and acetone for cleaning If there is any contact of these chemicals to the surface cl...

Page 22: ...y defect happens which cannot be handled by troubleshooting in this manual return it to the manufacturer Then Xenosys will take care of it If the qualified engineer determines that the defect comes fr...

Page 23: ...ight www xenosys co kr 23 Revision List Version No Release Date Revision Version 1 0 August 31 2015 1st draft Version 2 0 November 19 2015 2nd draft 100 2 11 16 TEL 032 875 9811 2 FAX 032 875 9813 www...

Reviews: