SAFETY & PRECAUTIONS 

 

Before the usage, you should read the manual & precautions carefully and use it properly. You 

should follow next procedures and warnings about the battery & other components to prevent 

any fire, injury, or damage to human body. 

 

  WARNING for Safety: 

1. Do not heat the product with microwave machine or oven.   

2. Do not dispose the battery into a fire.   

3. The product is not waterproof (Ordinary equipment, IPX0), so avoid the humidity and water. 

4.  Do  not  use  in  the  presence  of  a  flammable  anesthetic  mixture  with  air,  oxygen,  or  nitrous 

oxide. 

 

  WARNING for Power Unit: 

1.  Do  not  use  any  undesignated  charger  by  Xenosys.  If  any  damage  or  unexpected  hazard 

happens  by  the  usage  of  undesignated  charger,  the  manufacturer  is  free  from  the 

responsibility. 

2. In case of any oil spillage or liquid to inside of the product may cause fire or electric shock. 

Then turn off the power immediately and disconnect the power cord. 

3. Do not bend or twist the power cord excessively. It may cause fire or electric shock. 

4.  Do  not  touch  the  power  cord  with  wet hand  which  may  cause electric  shock  or  equipment 

damage. 

5.  Do  not  use  L2S15  with  connecting  directly  to  the  battery  pack  during  the  operation  or 

medical practice. 

Summary of Contents for XD LIGHT

Page 1: ...dLight System User Manual Optical Device Medical Device System Engineering XENOSYS CO LTD 2 Venture ro 100 beon gil Yeonsu gu 22013 Republic Korea TEL 82 32 875 9811 2 FAX 82 32 875 9813 www xenosys c...

Page 2: ...ble of Contents INTRODUCTION 3 SAFETY PRECAUTIONS 4 FEATURES 7 COMPONENTS 8 FUNCTIONS 9 OPERATING INSTRUCTION 11 BASIC TROUBLESHOOTING 16 SPECIFICATIONS 17 ELECTROMAGNETIC COMPATIBILITY 19 TRANSPORTAT...

Page 3: ...This product is the medical device and KFDA approval registration is described like below table Registration No 1909 Certificate No Gyeongin Jesin 07 86 Product Category I A General Instruments Class...

Page 4: ...esence of a flammable anesthetic mixture with air oxygen or nitrous oxide WARNING for Power Unit 1 Do not use any undesignated charger by Xenosys If any damage or unexpected hazard happens by the usag...

Page 5: ...ergent or chemical fluid to clean which may cause discoloration 8 Avoid the reach of children or pets 9 Maintain the following conditions for storing the product Environment for Storage Transportation...

Page 6: ...if the operating time is shortened after full charge we recommend exchanging new battery 7 Be careful on benzene thinner alcohol volatile flammable fluid and water If those chemicals penetrate the ba...

Page 7: ...ing 1 Battery Pack Imbedded DC3 62V 2950mAh Lithium Ion 2 Charger Input DC5V 2000mA Output DC4 2V 1500mA 3 Medical power supply Input AC100 240V 50 60Hz 0 3A Output DC5V 2000mA 3 Protection Classifica...

Page 8: ...xenosys co kr 8 COMPONENTS 1 Basic Components Control Unit DCU LED Lens Module DLM82 Medical Power Supply BPM010S05 Power Cord LPC Gown Clip GOC Screw driver Universal Clip 2 Optional Dental Anti curi...

Page 9: ...ower Supply BPM010S05 Refer to page 10 1 Power Cord LPC 1 Gown Clip GOC 1 Screw driver Universal Clip 1 Anti curing Filter LF0882 Dental Anti curing Filter For DLM82 1 Optional LED Lens Module DLM150...

Page 10: ...ble link LED Lens module can move up down and left right side Warning Do not use non Xenosys supplied power supply This will cause severe damage to the cradle main body which is also excluded from the...

Page 11: ...trol unit fully charged battery then connect LED lens module wire to the circular connector of the control unit B Operating Instructions 1 Finish the preparation and put the main body to waist belt or...

Page 12: ...ater or electrolyte flow into the main body 6 In case of malfunctioning stop using immediately and contact the dealer 7 Do not disassemble repair or modify the equipment by unauthorized personnel Caut...

Page 13: ...ep sound the power will shut down after 10 minutes Caution Please recharge when hearing beep sound and only a few moments light come which means the battery is not charged 2 Press the intensity change...

Page 14: ...ctor to control unit make XENOSYS logo facing in front and connect to the phone jack of control unit Prepare to connect After connected 2 How to disconnect Grab the metal part of LED lens module and r...

Page 15: ...ortable LED HeadLight System XD Light www xenosys co kr 15 F LED Lens Module attachment examples Rigid Headband TTL Loupe of Xenosys Flip up Loupe of Xenosys Normal glasses Protective goggle of Xenosy...

Page 16: ...ain Light comes on a few moments and turn off Check the battery remaining quantity Recharge the battery The light intensity is not enough Check the intensity is properly adjusted Adjust the intensity...

Page 17: ...Light System XD Light www xenosys co kr 17 SPECIFICATIONS 1 Measurement Weight A Control Unit DCU Size Refer to below photo Weight 105 g B LED Lens Module DLM82 Size Refer to below photo Weight 57 g 1...

Page 18: ...ation Electrical Specification Operating Power DC3 62V 550mA Operating Time About 22 hours 1st step mode Minimum About 11 hours 2nd step mode About 7 5 hours 3rd step mode About 5 5 hours 4th step mod...

Page 19: ...ty It is designed to protect the medical equipment from the harmful interruption This system occur electromagnetic interruption within the acceptable range And if it is not installed nor used properly...

Page 20: ...ght by hand hold it with two hands firmly and disconnect charger and power cord from the main body for safe transportation STORAGE 1 Maintain the following conditions for storing main products compone...

Page 21: ...t regularly to remove dirt and leave it dry for usage 2 Do not use volatile chemicals like benzene alcohol thinner and acetone for cleaning If there is any contact of these chemicals to the surface cl...

Page 22: ...y defect happens which cannot be handled by troubleshooting in this manual return it to the manufacturer Then Xenosys will take care of it If the qualified engineer determines that the defect comes fr...

Page 23: ...ight www xenosys co kr 23 Revision List Version No Release Date Revision Version 1 0 August 31 2015 1st draft Version 2 0 November 19 2015 2nd draft 100 2 11 16 TEL 032 875 9811 2 FAX 032 875 9813 www...

Reviews: