6 - 16
Discard Data
B8 Discards types of data. For example, you may want to discard Code
128 bar codes that begin with the letter A. In step 4 (
), select
6A (for Code 128), and in step 5, select 9999 (for all lengths). Enter
FE41B8 to compare and discard Code 128 bar codes that begin with
the letter A.
Syntax = B8.
Note: The B8 command must be entered after all other commands.
The Data Format must be
Required
B8 command to work. If Data Format is On, but Not Required (
), bar code data that meets the B8 format is scanned and output
as usual.
Other data format settings impact the B8 command. If Data Format
Non-Match Error Tone is
On
), the scanner emits an error
tone. If Data format Non-Match Error Tone is
Off
, the code is
disabled for reading and no tone is sounded.
Data Formatter
When Data Formatter is turned Off, the bar code data is output to the host as
read, including prefixes and suffixes.
You may wish to require the data to conform to a data format you have created
and saved. The following settings can be applied to your data format:
Data Formatter On, Not Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted.
Data Formatter On, Not Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is
found for a particular symbol, those prefixes and suffixes are not
transmitted. If a data format is
not found for that symbol, the prefixes and
suffixes
are transmitted.
Data Format Required, Keep Prefix/Suffix
Scanned data is modified according to your data format, and prefixes and
suffixes are transmitted. Any data that does not match your data format
requirements generates an error tone and the data in that bar code is not
transmitted. If you wish to process this type of bar code without generating
an error tone, see
Data Format Non-Match Error Tone
.
Data Format Required, Drop Prefix/Suffix
Scanned data is modified according to your data format. If a data format is
found for a particular symbol, those prefixes and suffixes are not
transmitted. Any data that does not match your data format requirements
generates an error tone. If you wish to process this type of bar code without
generating an error tone, see
Data Format Non-Match Error Tone
Data Formatter Off
Summary of Contents for 1900
Page 1: ...Xenon 1900 1910 Xenon 1902 1912 Granit 1910i 1911i Area Imaging Scanner User s Guide...
Page 20: ......
Page 32: ...xii...
Page 72: ...2 24 1200 2400 4800 9600 19200 38400 57 600 115 200...
Page 118: ...3 40...
Page 148: ...4 30...
Page 174: ...6 20...
Page 238: ...7 64...
Page 258: ...8 20...
Page 262: ...9 4...
Page 268: ...10 6...
Page 312: ...11 44...
Page 350: ...A 14...
Page 353: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message...