SB-02&05
User Manual
XELTEK Automatics
SB0X
XELTEK. 2019. All rights reserved.
User Manual
Rev. 03 - 5th MAY 2020
10 of 200
Module Auto.Pos
o
Use machine vision system for automatic position adjustment.
o
The current location of the sockets should not be too large for the corresponding
position configuration deviation, which cannot exceed the deviation range allowed by
the machine vision.
o
Minor adjustments can only be made within the range of machine vision deviations.
Clamp control (Applies only to superpro/sb05)
o
Clamp_[XX] - XX
:
Corresponding Programmer flags/locations
o
State
▪
Red- Closed
▪
Green - Open
o
On - Open
o
Off - Close
Positions of input/output
Tray - Activate the tray position adjustment interface
o
Click on the camera to activate the corresponding cell/slot.
Position adjustment of the input
o
Camera - activate the corresponding cell/slot
o
Save - Use the coordinates of the current XY axis as the XY coordinates of the cell
o
Auto Pos. - N/A
o
Camera(2)(Pick&Move) - N/A
o
AutoHeight - Test the height for the unit.
▪
Please make sure that there
’s a chip in the sockets.
▪
Please make sure that the air pressure sensor in right setting.
o
Pick - Pick up the chip in the cell.
o
Place - Place the chip back to the cell.