IFU ACTIVESOL FLEX en 10 17 V.3.
INSTALLATION AND DISASSEMBLY
During the installation and disassembly of the module, it is recommended to cover the module with material
which does not permeate light.
It is necessary to use insulated tools during installation to minimise the risk of electrocution.
The installation and disassembly must be executed in dry conditions.
It is forbidden to load the modules with tools or objects which may scratch the module’s surface
and damage the cells.
PLACE OF INSTALLATION
An optimal place for the module’s installation allows for maximisation of power generation, module security
against damage as well as easy and safe connection of receivers which will collect the generated current.
It is necessary to choose a place of installation that is most exposed to direct sunlight.
It is necessary to avoid shaded places and places in which a part of the module is shaded for a long period of
time.
Do not install the modules near sources of heat and combustible materials.
It is recommended to ensure air circulation on the module surface that is exposed to sunlight.
METHOD OF ASSEMBLY
The ACTIVESOL LIGHT & ULTRA modules may be assembled using assembly rings, double-sided tape, glue or
silicone. When installing flexible modules on surfaces with different thermal expansion coefficient (e.g. steel), rigid
mounting to the surface should be avoided. The installation method should allow the module to work naturally
without distortions, when the ambient temperature changes. When mounted, flexible panels ACTIVESOL LIGHT
should be supported on entire surfaces.
ELECTRICAL CONNECTION
In the case of installation of more than one module, it is possible to use a single or parallel connection.
Regardless of the connection, the modules of a single system should be equally exposed to sunlight.
SERIAL CONNECTION
The serial connection causes a voltage increase proportionate to the number of modules. In the case of the serial
connection, it is forbidden to exceed the system’s maximum voltage (1,000 VDC).
WARNING
In a serial connection, the modules must have the same parameters and derive from a single manufacturer.
In case of connecting more than 2 modules, the installation should be carried out by a qualified person with
proper authorisation.
PARALLEL CONNECTION
The parallel connection causes a circuit increase proportionate to the number of modules. It is recommended to
connect a maximum of 2 rows of ACTIVESOL LIGHT & ULTRA modules in a parallel circuit. In case of connecting more
rows, it is necessary to provide an additional security at each row (when the maximum reverse current exceeds the
acceptable circuit breaker load, the serial rows must be secured before they are connected to other rows).