xDEEP Ghost User Manual Download Page 10

9 Adjusting 2/2 

 

 

In the harness with quick-adjustment buckle you adjust the strap by pulling loose ends of the shoulder straps 
(tightening) or by bending the press of the buckle up (loosening).  

 

 

 
Guidelines for how to adjust NextGEN harness:  
 

 

In properly adjusted NextGEN harness the waist strap should be placed exactly on the waist (you need 
to properly adjust the height at which the plate is installed as well as the length of shoulder straps). 
Too high or too low location of the waist strap will decrease your comfort.  

 

 

In  NextGEN  harness  the  waist  strap  shall  be  fastened  so  that  it  is  placed  onto  shoulder  straps.  The 
fastening of the waist strap should press the shoulders straps to the body improving the adjustment of 
the  harness.  You  need  to  take  it  into  consideration  while  adjusting  the  harness  and  check  the 
adjustment of shoulder straps after you fasten the waist strap.  

 

 

The  length  of  the  crotch  strap  should  be  so  adjusted  that  after  the  fastening  the  waist  strap  falls 
downwards creating Y shape with the crotch strap.  
 

 

The crotch strap should not be too short since it could be more difficult to find it while putting on the 
harness.  

Fig.9. Strap adjustment  – step 1 

Fig.10. Strap adjustment  – step 2 

Fig.11. Adjustment of shoulder straps in easy-to-unfasten harness. 

Summary of Contents for Ghost

Page 1: ...User Manual...

Page 2: ...oughly In no way can this manual act as a substitute for professional diver training or course Therefore before you start using any of the products described in this manual make sure that you have rel...

Page 3: ...tified as compatible with 89 686 EWG directive as far as it contains air compatible with EN 12021 norm Regarding the lack of EN norms for safety requirements while the use of it takes place with mixtu...

Page 4: ...to damage done to the BC or an uncontrolled ascent For bringing objects heavier than 2kg use appropriate equipment such as a lift bag 7 To prevent the BC from damage avoid prolonged exposure of your...

Page 5: ...ess see Chapter 6 Optional droppable weights or trim pockets On the following pages of this manual we described particular elements of the system and also their configuration and adjustment 1 Compensa...

Page 6: ...e is made of metal which makes the inflator more resistant to freezing and it can be operated much longer than inflators made entirely of plastic The inflator is equipped with an inflator button 1 to...

Page 7: ...s from the waist strap if installed 2 Fix the pockets on the waist strap by interweaving the waist strap webbing through proper places in the weight pockets 3 With the use of bolts supplied with the p...

Page 8: ...pe of suit you use Together with GHOST system you can use the following types of trim pockets Standard trim pockets placed on straps to attach the tank or on additional strap of equal type placed anyw...

Page 9: ...oviding optimal trim and stability NextGEN harness is traditionally equipped with V type crotch strap which distributes pressure on a larger area and at the same time improves comfort in particular wh...

Page 10: ...the waist strap shall be fastened so that it is placed onto shoulder straps The fastening of the waist strap should press the shoulders straps to the body improving the adjustment of the harness You...

Page 11: ...llowing picture shows GHOST compensator optimally attached to aluminium 80cf tank commonly used in diving centres operating in warm water areas In order to help you find the perfect point where to att...

Page 12: ...BC in a reliable and safe manner you should connect the webbing as indicated in the pictures below Before connecting the tank carefully wet the connecting straps Otherwise they may loosen and the tank...

Page 13: ...ble as a result for shorter people to lower the diving tank and at the same time retain perfect trim and safe tank attachment The adapter and buoyancy compensator are mounted to the harness with the u...

Page 14: ...nto the quick connector step 2 as presented in the pictures below LP hose connection using the 1 st stage of the regulator must be made to the low pressure LP port only Connection to the HP port may r...

Page 15: ...atic dump valve is activated The automatic dump valve should open with a characteristic sound The air supply should stop immediately after release of the inflator button 5 Check the correctness of man...

Page 16: ...cy you should press the inflator button for a short moment If more air needs to be added to the BC press the inflator button for a short moment several times During release of air from the BC hold the...

Page 17: ...inse the BC inside press the purge button of the inflator and fill the BC approximately full with water by means of a garden hose spout or other source of fresh water Rotate the BC several times and n...

Page 18: ...ugh identical by all appearances may have slightly different properties which may negatively affect the working life of the BC The only maintenance procedure which may be performed by the user is rins...

Page 19: ...0 dTEX Mounting bolts displacement 11 cali 27 94 cm Dry weight without the harness 0 65 kg Inflator Type K type Working pressure range From 6 bar to 17 23 bar 250 PSI Permisible tank parameters Type S...

Page 20: ...xDEEP Ul Ogrodnik w 3 43 227 G ra Polska Tel 48 12 44 66 998 e mail biuro xdeep pl...