INSTALLATION & OPERATING INSTRUCTIONS

• This luminaire must be installed in accordance with the latest edition of the IET Wiring Regulations and local Building Regulation

by a qualified competent person.

• The mains power supply must be turned off before inspection, installation or removal of the luminaire, ensuring that the supply is

locked off to prevent inadvertently switching the supply on.

• It is the installer’s responsibility to ensure that the installation is suitable for the total load of the luminaire(s). The supply cable

fuses/circuit breakers must be correctly rated for the electrical load and taking into account for any transient inrush currents that

may occur.

• It is the installer’s responsibility to ensure that the environmental operating and storage conditions are complied with and that any

fire risks are considered.

• Do not perform insulation strength or insulation resistance tests on the installation with the luminaire(s) connected, this can

damage the luminaires and give erroneous readings.

• Do not loop-in supply cables at the luminaire supply terminals unless there is provision for 2-way connection at the terminals.

• The light source contained in this luminaire must only be replaced by Tamlite Lighting or an appointed service agent.

• Emergency lighting luminaires must be installed and maintained in accordance with the emergency lighting standard BS 5266-1.

• To ensure that the product warranty remains valid, the luminaire must be installed and maintained in accordance with these

installation instructions and the product must not be modified in any way.

 Luminaires marked with this symbol must not be covered with thermally insulating material.

 This symbol on covers over light sources indicates dangerous live parts do not operate the luminaire with this cover removed.

E (mm)

5

8

D (mm)

1

60

XCPSK67RGB

IP67

220-240V

50/60Hz

ta

-25°C to 40°

B (mm)

C (mm)

A (mm)

5000

12

880

A
B

C
D

E
F

G
H

I

LED Strip

Driver 

RGB Remote

Wire with DC connector

Mounting clip

Clip screw

Silicone glue

Silicone end cap 

RGB controller

x1

x1

x10

x20

x1

x1

x1

x1

x1

Summary of Contents for XCPSK67RGB

Page 1: ...t perform insulation strength or insulation resistance tests on the installation with the luminaire s connected this can damage the luminaires and give erroneous readings Do not loop in supply cables at the luminaire supply terminals unless there is provision for 2 way connection at the terminals The light source contained in this luminaire must only be replaced by Tamlite Lighting or an appointed...

Page 2: ...ntilated area only Spillage must be cleaned immediately No naked flames Keep out of reach of children WARNING IP20 IP67 Important information Remove the product from its packaging Measure the length of the strip required for the installation The strip can be cut to length at 50mm intervals at the indicated position Remove the foil seal from the silicone glue tube and install the nozzle PLEASE NOTE...

Page 3: ...ting surface Connect the controller to the power supply lead Connect the controller to the lead and observe Triangle to Triangle Remove the terminal covers from the LED driver Apply silicone glue in to the silicone end cap and cut end of the strip kit Insert the strip in to the end cap and ensure good seal with the silicone glue Continue to install the strip ensuring good contact with the mounting...

Page 4: ...ed button i e Blue button for Blue light Brightness control To change the brightness of the light press the button to increase or the button to decrease the intensity Dynamic mode The dynamic option can be switched on by pressing the FLASH STROBE SMOOTH or FADE button The colours will automatically change in a programmed tempo To switch off the dynamic mode press any colour button IP67 13 14 16 15...

Reviews: