ADVANCED SETTINGS - DUAL FUEL SWITCH
35
!
IMPORTANT: This feature can only be activated when used with the
TrueTouch™ Outdoor Wireless Temperature Transmitter and Receiver.
Please install the TrueTouch™ Outdoor Wireless Temperature Transmitter
and Receiver before activating this feature.
Increasing energy efficiency and reducing costs can be achieved by using the dual
fuel switch. Your heat pump can generally provide heat and comfort without assis-
tance to an outside temperature of just a few degrees below freezing. This tem-
perature is called the heat pump balance point. When the outside temperature is
above the balance point, the heat pump alone is sufficient for heating.
Once the outdoor temperature drops to the balance point the heat pump must be
assisted by your alternate energy source. When the outdoor temperature drops
below the systems normal crossover temperature (-12°C or -15°C), your heat pump
will stop operating and the alternate energy source will take over.
• HP Cut
ON
or
OFF
• Cut Temperature:
+
/
-
Temperature in Celsius (-5°c to 25°c)
+
/
-
Temperature in Fahrenheit (13°F to 41°F)
ADVANCED SETTINGS - SYSTEM CONFIGURATION
34
!
IMPORTANT: By inadvertently modifying system configuration settings, you
may seriously degrade HVAC system performance.
>>
Choose system heating and cooling equipment - remember all you need to do is toggle
the appropriate button until the correct setting appears.
• Choose
HEAT PUMP
or
2 STAGE HEAT PUMP
or
AIR CONDITIONING
or
NO
COMPRESSOR
- please review the wiring table and diagram for wiring instructions.
• Choose
FURNACE OFF
(No Furnace) or
ELECTRIC FURNACE
or
EMERGENCY
ELECTRICAL FURNACE
(additional electric furnace which will come on in emergency
mode in conjunction with electric furnace) or
GAS FURNACE
or
OIL FURNACE
or
2 STAGE GAS FURNACE
; please review the wiring table and diagram for wiring
instructions.
•
CYCLE RATE
: Set Maximum compressor cycles per hour. We recommend that the
factory default be maintained for optimal performance..
•
AUTO CHANGE
: Set the minimum difference between Auto Mode, Heat and Cool
temperature setpoints. We recommend that the factory default be maintained for
optimal performance.