Instruction Manual XC Tracer Maxx II
Rev 01 16.08.2022
XC Tracer Maxx II Configuration File
A few settings cannot be made directly on the vario. To change them, you have to connect XC
Tracer Maxx II with a USB-C cable to a computer, and only then switch on the vario by briefly
pressing the red button. Now XC Tracer Maxx II is active in USB mode. The SD card appears in the
Windows Explorer or in the Finder of the Mac. The operating instructions are stored on the SD
card as a PDF and the configuration file with the name XC_Tracer_Maxx II.txt. In this file the
variometer can be adapted to the personal needs. The individual setting options are described
below:
# XC Tracer Maxx II Configuration File
serialNumber= 688D2E4C8100
Serial number of XC Tracer Maxx II, is used for the IGC logger.
RadioID=2000CA
Radio ID von FANET
RadioFirmwareVersion=7.07-0.9.54
Version of radio firmware
RadioExpireDate=20231201
Expiry date of the radio firmware
firmwareVersion=XC_Tracer_Maxx II_R01
Indicates the
device’s
firmware version.
reset=no
Setting
reset=yes
resets XC Tracer Maxx II to the factory default settings. Reset=no is the default
setting. After a reset reset=no will automatically be set in the config file.
# supported protocols are None, XCTRACER, LK8EX1, LXWP0 or LXWPW.
Select the BLE protocol her. NB. Only one protocol can be selected at once. Please check at
www.xctracer.com which protocol to choose for your app. LXWPW is like LXWPO, but with the
information of the calculated wind.
stringToSend=LXWP0
In this case the LXWPO protocol will be will be used.
# name of BLE service
bleName=XCT
A name for the BLE service can be assigned here, up to 14 numbers and letters are possible.
Please do not use a hyphen, some Android Apps have problems with it.
# logger configuration
pilotName=Koni Schafroth