13
6. Installation
6.1
Fixture Installation
Verify that the safety cable is undamaged and can bear at least 10 times the weight of
the fixture. Verify that the structure can bear at least 10 times the weight of all
installed fixtures, clamps, cables, auxiliary equipment, etc.
Bolt each clamp securely to a clamp bracket with an M12 bolt (grade 8.8 or better)
and lock nut.
Align a clamp with 2 mounting points in the base. Insert the fasteners into the base
and turn both levers a full 1/4-turn clockwise to lock. Install the second clamp.
If the truss can be lowered, fixtures can be clamped on directly from the double flight
case. If the fixture must be lifted, block access under the work area. Working safely
from a stable platform, hang the fixture on the truss with the arrow towards the area
to be illuminated. Tighten the rigging clamps.
Install a safety cable that can bear at least 10 times the weight of the fixture. The
attachment point is designed to fit a carabiner clamp.
The minimum space between fixtures in array is 900mm.