background image

Installation and Operation

4

975-0271-01-01

Installation and Operation

To install PowerSource 1800:

1.

Plug the power cord directly into a wall outlet (not into a surge protector or 
power strip).

2.

Connect your electronic devices or small household appliances to the five 
AC outlets of the PowerSource 1800.

3.

Turn on the unit by pressing the Power button for at least half a second. The 
green AC Power LED confirms that the PowerSource 1800 is on and ready 
to provide backup power.
When the battery needs recharging, the LED screen flashes “CHG” 10 times, 
then the battery capacity (%) once. This pattern of flashing continues until 
the battery capacity reaches 100% and “FUL” appears on the screen.

Backup Power Feature

The unit’s five 

120 VAC

 outlets are permanently backed up by the internal battery 

when utility power is not available. To activate the AC outlets for backup 
operation, turn on the unit using the Power button. During a power outage or 
other utility problem (such as brownouts and over-voltages), PowerSource 1800 
will keep running the connected products for up to 10 hours, depending on the 
power draw of your application (see “Run Time on Typical Products” and “Run 
Time for Combinations of Products”). When utility power is restored, the unit 
automatically recharges its internal battery.

Operation Guide

WARNING: Shock Hazard

If the input plug is connected and utility power is present, the outlets will be 
energized. The front panel ON/OFF button will not turn these outlets off.

Important:

PowerSource 1800 should be used or stored in a clean, temperature-

controlled, indoor area away from direct sunlight, moisture or conductive contaminants.

Important:

PowerSource 1800 must be charged before storage or use.

 This will 

prevent the battery inside from totally discharging and will ensure extended usage run 
time. A complete charge may take up to 15 hours when recharged from a 120 VAC wall 
outlet.

CAUTION: Equipment Damage

Do not plug surge-protected power bars into 

the unit

’s 120 VAC outlets.

Do not connect an AC power source to the 120 VAC outlets.

Do not connect the unit’s AC power cord to its 120 VAC outlets.

Important:

During installation when placing the unit, allow a minimum of 3 inches 

of space around the unit for optimal ventilation.

Important:

When connected to utility power, 

the unit 

automatically provides AC 

power from its internal battery when the utility voltage falls below 105 VAC.

Condition

LED status

Alarm status

Alarm stops sounding when…

Normal operation

: Utility power is available and unit is turned on. 

The internal battery is fully charged.

AC Power LED and Charged/Charging LED 
are solid green. Screen shows “FUL.”

None

Not applicable

Backup power

: Utility power is not available. Unit supplies power 

from its internal battery.

Battery LED is flashing amber.

One beep when the power outage 
occurs.

Utility power becomes available; unit resumes 
normal operation or when it is turned off. 

Low battery warning

: During backup power operation, the 

internal battery is close to being completely discharged.

Battery LED is flashing amber. Screen 
shows Error code E05.

Beeps once every 2 seconds.

Utility power becomes available; unit resumes 
normal operation or when it is turned off. 

Overload shutdown

: During backup power operation an AC outlet 

overload was detected.

Fault LED on. Screen shows Error code E03. One beep per second. Unit shuts 

down after 10 seconds.

Not applicable

Under-voltage shutdown

: During backup power operation the 

battery power has been completely exhausted. No power is 
available at the AC outlets.

Fault LED on. Screen shows error code E01. One beep per second. Unit shuts 

down after 10 seconds.

Not applicable. Unit starts recharging the 
internal battery when utility power is restored. 
Turn on the unit to restore normal operation.

Over-temperature warning

: During backup power operation, the 

unit is close to shutting down to protect its internal circuitry from 
high temperatures.

Fault LED on. Screen shows error code E06. Beeps once every 2 seconds.

Better ventilation is provided to the unit, or the 
unit enters over-temperature shutdown, or the 
unit is turned off.

Over-temperature shutdown

: Unit has shut down to protect its 

internal circuitry from high temperatures.

Fault LED on. Screen shows error code E04. One beep per second.

The unit is turned off or when the unit shuts 
down.

Recharging internal battery

: Unit is recharging its internal 

battery after utility power has been restored. Internal fan is running.

AC Power LED is green. Charged/Charging 
LED flashes amber. Screen shows “CHG” 
alternating with battery capacity (%).

No sound

Not applicable. Screen shows “FUL” when unit 
is completely charged.

Summary of Contents for xpower PowerSource 1800

Page 1: ...S HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION THE ACCURACY CANNOT BE GUARANTEED APPROVED XANTREX CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT www xantrex com Date and Revision September 2007 Revision B Part Number 975 0271 01 01 Product Number 852 1802 Contact Information IMPORTANT SAFETY INSTRUCTIONS Operating the XPower PowerSource 1800 incorrectly or...

Page 2: ... heat including space heaters and pellet stove igniters Visit www xantrex com for higher power solutions Precautions for Using Rechargeable Appliances Most rechargeable battery operated equipment uses a separate charger or transformer that is plugged into an AC receptacle and produces a low voltage charging output Some chargers for rechargeable batteries can be damaged if connected to the PowerSou...

Page 3: ...internal battery 4 LED Screen indicates charging status power draw from the PowerSource 1800 W when providing backup power or battery capacity The screen also shows error codes to aid troubleshooting 5 Select Button displays PowerSource 1800 Battery Level or Output Power W 6 Charged Charging LED green illuminates when PowerSource 1800 is fully recharged and flashes while PowerSource 1800 is rechar...

Page 4: ...d the unit for optimal ventilation Important When connected to utility power the unit automatically provides AC power from its internal battery when the utility voltage falls below 105 VAC Condition LED status Alarm status Alarm stops sounding when Normal operation Utility power is available and unit is turned on The internal battery is fully charged AC Power LED and Charged Charging LED are solid...

Page 5: ...each the end of their service life and if you choose not to have a qualified technician replace them the PowerSource 1800 itself is no longer of use The internal batteries may be replaced following the guidelines in Battery Replacement above Because the internal batteries contain lead which can be hazardous to the environment the batteries and the PowerSource 1800 should be recycled or safely disp...

Page 6: ...is discharged and utility power is not available at the wall outlet Ensure power is available at the wall outlet No power available at the 120 VAC outlets AC outlet has been overloaded or the supplementary protector has tripped Reduce the number of products plugged into the AC outlets Check the supplementary protector at the back of the unit If necessary reset the breaker by pushing it fully inwar...

Page 7: ...ler is unable to provide service contact Xantrex directly at What proof of purchase is required In any warranty claim dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantrex Proof of purchase may be in any one of the following forms The dated purchase receipt from the original purchase of the prod...

Page 8: ...MAGES LOSSES COSTS OR EXPENSES HOWEVER ARISING WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT RESTRICTION ANY ECONOMIC LOSSES OF ANY KIND ANY LOSS OR DAMAGE TO PROPERTY ANY PERSONAL INJURY ANY DAMAGE OR INJURY ARISING FROM OR AS A RESULT OF MISUSE OR ABUSE OR THE INCORRECT INSTALLATION INTEGRATION OR OPERATION OF THE PRODUCT Exclusions If this product is a consumer product federal law does not allo...

Reviews: