background image

Features

975-0271-01-01

3

Features

1800

12

0V

AC

 60

Hz

     

   1

5A

 M

ax

.

by

1

2

3

4

5

6

7

8

10

9

Rear View

Feature

Description

1

Fault LED

 illuminates red when PowerSource 1800 has an operation fault.

2

Power button

 turns PowerSource 1800 on and off when utility power is not 

available.

Pressing and holding the Power button for at least half a second turns the 
unit on or off when utility power is not present.

When utility power is available, the Power button cannot be used to 
remove power from any or all of the five AC outlets

3

AC Power/Battery LED

 illuminates green when utility power is available 

and flashes amber when PowerSource 1800 is providing backup power using 
its internal battery.

4

LED Screen 

indicates charging status, power draw from the PowerSource 

1800 (W) when providing backup power, or battery capacity (%). The screen 
also shows error codes to aid troubleshooting.

5

Select Button

 displays PowerSource 1800 Battery Level (%) or Output 

Power (W).

6

Charged/Charging LED

 (green) illuminates when PowerSource 1800 is 

fully recharged and flashes while PowerSource 1800 is recharging.

7

AC Power Cord

8

Blue LED 

illuminates the rear AC outlets when AC power is available.

9

15 A supplementary protector 

protects the PowerSource 1800 AC outlets 

and your applications from overload conditions.

10

Five 120V AC outlets

 (One in the front, four in the rear) for powering office 

equipment and household appliances that draw a maximum total of 1800 
watts (1440 watts continuous). All outlets are surge protected and backed up 
by the PowerSource 1800 internal battery.

Summary of Contents for xpower PowerSource 1800

Page 1: ...S HAVE BEEN TAKEN TO MAINTAIN THE ACCURACY OF THE TRANSLATION THE ACCURACY CANNOT BE GUARANTEED APPROVED XANTREX CONTENT IS CONTAINED WITH THE ENGLISH LANGUAGE VERSION WHICH IS POSTED AT www xantrex com Date and Revision September 2007 Revision B Part Number 975 0271 01 01 Product Number 852 1802 Contact Information IMPORTANT SAFETY INSTRUCTIONS Operating the XPower PowerSource 1800 incorrectly or...

Page 2: ... heat including space heaters and pellet stove igniters Visit www xantrex com for higher power solutions Precautions for Using Rechargeable Appliances Most rechargeable battery operated equipment uses a separate charger or transformer that is plugged into an AC receptacle and produces a low voltage charging output Some chargers for rechargeable batteries can be damaged if connected to the PowerSou...

Page 3: ...internal battery 4 LED Screen indicates charging status power draw from the PowerSource 1800 W when providing backup power or battery capacity The screen also shows error codes to aid troubleshooting 5 Select Button displays PowerSource 1800 Battery Level or Output Power W 6 Charged Charging LED green illuminates when PowerSource 1800 is fully recharged and flashes while PowerSource 1800 is rechar...

Page 4: ...d the unit for optimal ventilation Important When connected to utility power the unit automatically provides AC power from its internal battery when the utility voltage falls below 105 VAC Condition LED status Alarm status Alarm stops sounding when Normal operation Utility power is available and unit is turned on The internal battery is fully charged AC Power LED and Charged Charging LED are solid...

Page 5: ...each the end of their service life and if you choose not to have a qualified technician replace them the PowerSource 1800 itself is no longer of use The internal batteries may be replaced following the guidelines in Battery Replacement above Because the internal batteries contain lead which can be hazardous to the environment the batteries and the PowerSource 1800 should be recycled or safely disp...

Page 6: ...is discharged and utility power is not available at the wall outlet Ensure power is available at the wall outlet No power available at the 120 VAC outlets AC outlet has been overloaded or the supplementary protector has tripped Reduce the number of products plugged into the AC outlets Check the supplementary protector at the back of the unit If necessary reset the breaker by pushing it fully inwar...

Page 7: ...ler is unable to provide service contact Xantrex directly at What proof of purchase is required In any warranty claim dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantrex Proof of purchase may be in any one of the following forms The dated purchase receipt from the original purchase of the prod...

Page 8: ...MAGES LOSSES COSTS OR EXPENSES HOWEVER ARISING WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT RESTRICTION ANY ECONOMIC LOSSES OF ANY KIND ANY LOSS OR DAMAGE TO PROPERTY ANY PERSONAL INJURY ANY DAMAGE OR INJURY ARISING FROM OR AS A RESULT OF MISUSE OR ABUSE OR THE INCORRECT INSTALLATION INTEGRATION OR OPERATION OF THE PRODUCT Exclusions If this product is a consumer product federal law does not allo...