Specifications
A-2
975-0162-01-01
AC Power Section
Output power
•
Continuous output power
•
Five minute AC output power
•
AC output surge capacity
320 W
400 W
600 W
Output voltage
115 ± 10 V AC RMS
Output frequency
60 Hz ± 4 Hz
Output wave form
modified sinewave
No load current draw
<0.20 A DC
Input voltage range
10.5 to 15.0 V DC
Low battery alarm
11.0 V DC
Low battery shutdown
10.5 V DC
High battery voltage shutdown
Yes, automatic reset
Over temperature shutdown
Yes, automatic reset
Overload shutdown
Yes, automatic reset
AC output short circuit protection
Yes, automatic reset
Fuse (internal)
2 x 25 A or 1 x 50 A
Operating temperature range
32 – 104 ºF
(0 – 40 ºC)
Storage temperature range
32 – 86ºF
(0 – 30 ºC)
Internal Battery Charging Controller System
AC Charger bulk charging current
750 mA
Peak charging voltage (nominal)
14.2 V
Charge restart voltage (nominal)
12.9 V
Float charge after full charge is completed
(nominal)
1 mA
AC Charger input socket maximum current
2.5 A