background image

4–1

4

Troubleshooting

Chapter 4

 will help you identify the source of most problems that can 

occur with the inverter.

If you have a problem with the inverter, please review this chapter before 
contacting place of purchase.

If you are unable to solve a problem and need to contact place of 
purchase, record the information in the form 

“Information About Your 

System” on page WA–5

Common Problems

Buzz in Audio Equipment

Some inexpensive stereo systems may emit a buzzing noise from their 
loudspeakers when operated from the inverter. This occurs because the 
power supply in the audio system does not adequately filter the modified 
sine wave produced by the inverter. The only solution is to use a sound 
system that has a higher quality power supply.

Television Reception

When the inverter is operating, it can interfere with television reception 
on some channels. If interference occurs, try the following:

1. Make sure that the chassis ground screw on the rear of the inverter is 

solidly connected to the ground system of your vehicle.

2. Make sure that the television antenna provides an adequate (“snow-

free”) signal, and that you are using good quality cable between the 
antenna and the television.

3. Keep the cables between the battery and the inverter as short as 

possible, and ensure that the positive and negative cables are run very 
close to each other. This minimizes radiated interference from the 
cables.

4. Move the television as far away from the inverter as possible.

5. Do not operate high power loads with the inverter while the television 

is on.

XPower_Inverter_5000_Owners_Guide.book  Page 1  Friday, April 4, 2008  2:59 PM

Summary of Contents for XPower 5000

Page 1: ...by XPower Inverter 5000 Owner s Guide...

Page 2: ...r Documentation UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TECHNOLOGY INC XANTREX A MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED...

Page 3: ...ers for this information This Guide does not provide installation instructions Installation should be handled by qualified installers including licensed technicians and electricians Qualified installe...

Page 4: ...ooting the XPower Inverter 5000 Appendix A contains physical and electrical specifications of the XPower Inverter 5000 Conventions Used The following conventions are used in this guide Related Informa...

Page 5: ...that wiring is in good condition adequately rated and not undersized Do not operate the XPower Inverter 5000 with damaged or substandard wiring 5 Do not operate the XPower Inverter 5000 if it has rec...

Page 6: ...line powered machinery fuel tanks as well as joints fittings or other connections between components of the fuel system 4 Make sure the area around the battery is well ventilated 5 Never smoke or allo...

Page 7: ...separate charger or transformer that is plugged into an AC receptacle and produces a low voltage charging output Some chargers for small rechargeable batteries can be damaged if connected to the XPow...

Page 8: ...viii...

Page 9: ...e of Use 1 2 Comprehensive Protection 1 2 2 Features AC Panel 2 2 DC Panel 2 4 Remote Switch 2 5 3 Operation Turning the Inverter On and Off 3 1 Operating Several Loads at Once 3 2 Display Screen 3 2...

Page 10: ...shooting Common Problems 4 1 Buzz in Audio Equipment 4 1 Television Reception 4 1 Troubleshooting Reference 4 2 A Specifications Electrical Performance A 1 Physical Specifications A 2 Accessory A 2 Wa...

Page 11: ...Vs light and heavy duty truck applications and other in vehicle applications The inverter provides up to 4000 W of continuous power It is designed to handle loads such as microwaves refrigerators free...

Page 12: ...voltage drops below 10 5 V This feature will limit battery discharge High battery voltage shutdown Shuts the inverter down automatically if the input voltage rises to 15 5 V or more Overload and shor...

Page 13: ...2 1 2 Features Chapter 2 Features describes the main features of the XPower Inverter 5000 Familiarize yourself with them before operating the inverter...

Page 14: ...red indicates the inverter has shut down due to inverter overload over temperature under voltage over voltage AC output short circuit or AC back EMF backfeed protection shutdown 3 Power light green i...

Page 15: ...AC output power 7 Remote On Off Switch Connector Port For connecting the Remote On Off Switch The remote switch and a 10 foot communications cable is included with the inverter 8 Two duplex GFCIs Each...

Page 16: ...r sparks Risk of fire andexplosion Do not install near batteries in machinery space or area in which ignition protected equipmentis required Shock Hazard Do not open No serviceable parts inside INPUT...

Page 17: ...s control circuit on and off This switch is not a power disconnect switch Disconnect DC power before working on any circuits connected to the inverter 2 Communications Cable is 10 feet 3 m long This...

Page 18: ...2 6...

Page 19: ...ry To turn the inverter on and off from the remote switch Move the On Off switch to the On position to turn the inverter on Move the On Off switch to the Off position to turn the inverter off When the...

Page 20: ...ress the Display Function button The VOLTAGE CURRENT and AC POWER lights indicate what information the screen is showing Battery Voltage Indicator The BATTERY VOLTAGE INDICATOR indicates the DC voltag...

Page 21: ...1 15 V Optimum Performance 12 0 13 0 V Low Voltage Alarm 11 0 V or less The audible low battery alarm sounds Low Voltage Shutdown less than 10 5 V The inverter shuts down to protect the battery from b...

Page 22: ...rt the motor this low voltage condition may be why the motor won t start Make sure that the battery connections are good and that the battery is fully charged If the connections are good and the batte...

Page 23: ...ust and dirt Recharging Your Batteries When possible recharge your batteries when they are about 50 discharged or earlier This gives the batteries a much longer life cycle than recharging when they ar...

Page 24: ...3 6...

Page 25: ...solution is to use a sound system that has a higher quality power supply Television Reception When the inverter is operating it can interfere with television reception on some channels If interference...

Page 26: ...hutdown E05 warning code is ignored See possible causes under error 3 in this table See solution under error 5 in this table 2 E02 Flashing Fault LED Flashing Alarm Beeping Inverter is in overvoltage...

Page 27: ...nder Voltage Warning Alarm is on Poor battery condition Poor DC wiring Charge the battery Install a new battery Use proper cable size and lengths and make solid connections For more information refer...

Page 28: ...at cannot accurately read the RMS voltage of a modified sine wave Use a true RMS reading voltmeter such as the Fluke 87 10 N A Low output voltage on a true RMS reading voltmeter Low input voltage and...

Page 29: ...ut not on the other then the GFCI protection on the outlet may have tripped Disconnect all loads and push the Reset button on the GFCI outlet Reconnect the load to the receptacle that was tripped and...

Page 30: ...4 6...

Page 31: ...0000 W Output power at 40 C 104 F ambient temperature and 12 Vdc input Maximum continuous output power 3500 W Max output current Continuous 5 minute rating 33 Aac 41 Aac Output voltage range 120 Vac R...

Page 32: ...75 0376 01 01 Physical Specifications Accessory Length 18 1 2 47 cm Width 8 20 cm Height 6 1 4 16 cm Weight 24 1 lb 10 9 kg Remote On Off switch Part number 100 0830 01 01 On Off Switch with 10 foot c...

Page 33: ...e parts or products of original or improved design in the repair or replacement If Xantrex repairs or replaces a product its warranty continues for the remaining portion of the original Warranty Perio...

Page 34: ...the product if it has been subjected to fire water generalized corrosion biological infestations or input voltage that creates operating conditions beyond the maximum or minimum limits listed in the X...

Page 35: ...Authorization Policy Before returning a product directly to Xantrex you must obtain a Return Material Authorization RMA number and the correct factory Ship To address Products must also be shipped pre...

Page 36: ...se or incorrect installation if other conditions of the warranty have not been met or if no dated proof of purchase is available your unit may be serviced or replaced for a flat fee To return your pro...

Page 37: ..._ Type of installation e g RV truck ___________________________ Length of time inverter has been installed ___________________________ Battery battery bank size ___________________________ Battery typ...

Page 38: ...WA 6...

Reviews: