background image

  

Even with the output off the load is still connected to the power supply output stage. Do not apply 
external voltages in excess of 50V to the power supply terminals or damage may result. 

The output is protected from reverse voltages by a diode; the continuous reverse current must not 
exceed 3 Amps, although transients can be much higher. 

Ventilation 

The power supply is very efficient but nevertheless can generate significant heat at full power. 
The supply relies on convection cooling only and it is therefore important that ventilation is never 
restricted if performance and safety are to be maintained. If the supply is mounted in a restricted 
space, eg. a 19 inch rack, then adequate ventilation must be ensured by using, for example, a fan 
tray. 

Maintenance 

The Manufacturers or their agents overseas will provide repair for any unit developing a fault. 
Where owner wish to undertake their own maintenance work, this should only be done by skilled 
personnel in conjunction with the service manual which may be purchased directly from the 
Manufacturers or their agents overseas. 

Fuse 

The correct fuse type for both AC supply ranges is: 

10 Amp 250V HBC time-lag, 5 x 20mm. 

Make sure that only fuses of the required rated current and specified type are used for 
replacement. The use of makeshift fuses and the short-circuiting of fuse-holders is prohibited. 

To replace the fuse, first disconnect the instrument from the AC supply. Remove the 6 cover 
securing screws and lift off the cover. Replace the fuse with one of the correct type and refit the 
cover. 

Note that the main function of the fuse is to make the instrument safe and limit damage in the 
event of failure of one of the switching devices. If a fuse fails it is therefore very likely that the 
replacement will also blow, because the supply has developed a fault; in such circumstances the 
instrument will need to be returned to the manufacturer for service.  

Cleaning 

If the PSU requires cleaning use a cloth that is only lightly dampened with water or a mild 
detergent. Polish the display window with a soft dry cloth. 

WARNING! TO AVOID ELECTRIC SHOCK, OR DAMAGE TO THE PSU, NEVER ALLOW 
WATER TO GET INSIDE THE CASE. TO AVOID DAMAGE TO THE CASE OR DISPLAY 
WINDOW NEVER CLEAN WITH SOLVENTS. 

  

 

11 

Summary of Contents for XPF 35-10

Page 1: ...XPF Series Dual Output 35V 10A Powerflex DC Power Supply XPF 35 10 Operating Manual...

Page 2: ...e the property of their respective owners and are used herein for identification purposes only Notice of Copyright Xantrex International All rights reserved Disclaimer UNLESS SPECIFICALLY AGREED TO IN...

Page 3: ...Connexions 14 Op ration 14 Maintenance 16 Bedienungsanleitung auf Deutsch Sicherheit 17 Installation 18 Anschl sse 19 Betrieb 19 Wartung 22 Istruzioni in Italiano Sicurezza 23 Installazione 24 Collega...

Page 4: ...ypically 5m in constant voltage mode Typically 5k in constant current mode voltage limit at max Output Protection Forward protection by Over Voltage Protection OVP trip maximum voltage that should be...

Page 5: ...ding 1 digit GENERAL AC Input 110V 120V AC or 220V 230V AC 10 50 60Hz Installation Category II Power Consumption 600VA max Operating Range 5 C to 40 C 20 TO 80 RH Storage Range 40 C to 70 C Environmen...

Page 6: ...on is prohibited The protective action must not be negated by the use of an extension cord without a protective conductor When the instrument is connected to its supply terminals may be live and openi...

Page 7: ...ormance A According to EN61326 the definitions of performance criteria are Performance criterion A During test normal performance within the specification limits Performance criterion B During test te...

Page 8: ...ELLOW EARTH Safety Earth Symbol When fitting a fused plug a 5 amp fuse should be fitted inside the plug As the colours of the wires in the mains lead of this apparatus may not correspond with the colo...

Page 9: ...UT The OUTPUT terminals are rated at 15A Remote sense connections to the load if required are made from the positive and negative SENSE terminals Switch the LOCAL REMOTE switch to REMOTE when remote s...

Page 10: ...the maximum voltage that can be generated The CI lamp lights to show constant current mode Instantaneous Current Output The current limit control can be set to limit the continuous output current to...

Page 11: ...put terminals be touched when the unit is switched on under such use All connections to the terminals must be made with the power switched off on all units It should be noted that the unit can only so...

Page 12: ...directly from the Manufacturers or their agents overseas Fuse The correct fuse type for both AC supply ranges is 10 Amp 250V HBC time lag 5 x 20mm Make sure that only fuses of the required rated curr...

Page 13: ...en disconnected from all voltage sources but will be safely discharged about 5 minutes after switching off power Any adjustment maintenance and repair of the opened instrument under voltage shall be a...

Page 14: ...trol to 12 1V current control to maximum Switch output ON set rheostat so that current is 10 0A ensure CV mode is maintained Adjust VR5 VR105 power limit until the UNREG l e d just lights back off VR5...

Page 15: ...conducteur de protection car ceci annulerait sa capacit de protection Lorsque l instrument est reli au secteur il est possible que les bornes soient sous tension et par suite l ouverture des couvercle...

Page 16: ...s nus MARRON SECTEUR SOUS TENSION BLEU SECTEUR NEUTRE VERT JAUNE TERRE Symbole Terre de protection Lors du montage d une fiche fusible mettre un fusible de 5 A l int rieur de la fiche Il est possible...

Page 17: ...l inf rieur indique maintenant le courant de charge v ritable Tension constante Les commandes de VOLTAGE approximative et de pr cision permettent de r gler la tension de sortie la commande de CURRENT...

Page 18: ...ent un condensateur lectrolytique au point de connexion de charge La chute de tension de chaque fil de sortie ne doit pas d passer 0 5 V Placer le commutateur LOCAL REMOTE en position LOCAL lorsque la...

Page 19: ...ilation ad quate par exemple au moyen d un plateau de ventilateur Maintenance Le Constructeur ou ses agents l tranger r pareront tout bloc qui tombe en panne Si le propri taire de l appareil d cide d...

Page 20: ...Schutzwirkung darf nicht durch Verwendung eines Verl ngerungskabels ohne Schutzleiter aufgehoben werden Ist das Ger t an die elektrische Versorgung angeschlossen so k nnen die Klemmen unter Spannung...

Page 21: ...gung so ist es wie folgt anzuschlie en BRAUN STROMF HRENDER LEITER BLAU NULLEITER GR N GELB SCHUTZLEITER Schutzleitersymbol Bei Steckern mit eingebauten Sicherungen sollte eine 5 Ampere Sicherung verw...

Page 22: ...ch wie vor die Sollspannung an w hrend die untere Anzeige jetzt den tats chlichen Verbraucherstrom anzeigt Konstantspannung Die Ausgangsspannung l sst sich mit dem Grob und Feinregelknopf f r Spannung...

Page 23: ...h ht Bei hohen Stromst rken k nnen sich hieraus erhebliche Unterschiede zwischen der angezeigten Quellenspannung und der tats chlichen Lastspannung ergeben bei zwei 20 m Anschlussleitungen ergibt sich...

Page 24: ...Schraubendreher verstellbare und mit SET OVP bezeichnete Schraube des voreingestellten Potentiometers eingestellt die ber ein entsprechendes Loch in der Fronttafel zug nglich ist Durch Drehung im Uhr...

Page 25: ...trennen Dann die 6 Geh usebefestigungsschrauben entfernen und Geh use abheben Durchgebrannte Sicherung entfernen und durch geeigneten Typ ersetzen Danach Geh use wieder montieren Zu beachten ist dabei...

Page 26: ...e La protezione non deve essere negata attraverso l uso di un cavo di estensione privo del filo di collegamento a terra Quando lo strumento alimentato alcuni morsetti sono sotto tensione e l apertura...

Page 27: ...llegare come segue MARRONE LINEA BLU NEUTRO VERDE GIALLO TERRA Simbolo di sicurezza TERRA Quando si collega una spina fornita di portavalvola una valvola fusibile da 5A deve essere montata nella spina...

Page 28: ...stata ma quello inferiore ora legge la corrente attuale del carico Tensione costante La tensione in uscita si regola attraverso i controlli grossolano e fine di VOLTAGE tensione il controllo di CURREN...

Page 29: ...cavi di collegamento corti e di sezione grossa ma quando necessario lo si pu eliminare completamente usando la facilit di rilevamento a distanza In questo caso i cavi di rilevamento devono essere coll...

Page 30: ...do il pulsante sotto il potenziometro Se per qualsiasi ragione la tensione sull uscita eccede il limite di protezione di sovratensione impostato anche a causa di una tensione esterna forzata scatta l...

Page 31: ...fusibile bruciato con un altro del tipo corretto e rimettere a posto il coperchio Si voglia notare che la funzione principale del fusibile quella di rendere lo strumento sicuro e di limitare eventual...

Page 32: ...interrupci n intencional La acci n protectora no debe negarse por el uso de una extensi n de cable sin conductor protector Cuando el instrumento est conectado a su suministro es posible que queden si...

Page 33: ...r conectar como sigue MARR N CORRIENTE DE RED AZUL NEUTRO DE RED VERDE AMARILLO TIERRA S mbolo de Seguridad de Tierra Cuando se instale un enchufe fusibleado el enchufe debe llevar un fusible de 5 amp...

Page 34: ...de corriente actual Voltaje constante La salida de voltaje se ajusta mediante el control VOLTAGE de voltaje grueso y fino el control CURRENT de corriente fija la corriente m xima que puede suministrar...

Page 35: ...iento entre cada salida y cable del detector Esto se puede lograr ya sea enroscando los cables juntos o usando un cable coaxial blindado detector por el centro Un condensador electrol tico directament...

Page 36: ...a seguridad Si el suministro est montado en un espacio restringido p ej un estante de 48 cent metros se debe asegurar una ventilaci n adecuada usando por ejemplo una bandeja de ventilador Mantenimient...

Page 37: ...and return shipment to the customer via a Xantrex selected non expedited surface freight within the contiguous United States and Canada Alaska and Hawaii are excluded Contact Xantrex Customer Service...

Page 38: ...HANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT REQUIRED UNDER APPLICABLE LAW TO APPLY TO THE PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIOD STIPULATED UNDER THIS LIMITED WARRANTY IN...

Page 39: ...reached during work hours A brief description of the problem 3 Ship the unit prepaid to the address provided by your Xantrex customer service representative If you are returning a product from outside...

Page 40: ...chnology Inc 8999 Nelson Way Burnaby British Columbia Canada V5A 4B5 604 422 8595 Tel 604 421 3056 Fax 800 667 8422 Toll Free North America prg info xantrex com www xantrex com 975 0106 01 02 48511 07...

Reviews: