Remote Operation
SCPI Commands for Digital Interfaces
158
Operating Manual for XDC Series Power Supply
IEEE 488.2 Status and Event Commands
Clear Status Command
Clears all Event Registers, including the Status Byte, the Standard Event Status and
the Error Queue.
Command:
*CLS
SCPI equivalent for multichannel use:
STATus[<channel>]:CLEar
Standard Event Status Enable Register
The Event Summary Enable command determines which bits in the Standard Event
Status Register are summarized in the Event Summary Bit (ESB) of the Status Byte.
The Power-on Status Clear command determines if the Standard Event Status Enable
Register is cleared at power-on.
E.g.
Sending "*ESE 16" sets bit 4 of the Standard Event Status Enable Register. This will
cause the Event Summary bit (ESB) in the Status Byte to be set whenever the
Execution Error bit (bit 4) in the Standard Event Status Register gets set.
Command:
*ESE <status-enable>, *ESE?
SCPI equivalent for multichannel use:
STATus[<channel>]:STANdard:ENABle <status-enable>
STATus[<channel>]:STANdard:ENABle?
Standard Event Status Register
The Standard Event Status Register query allows the user to determine the current
contents of the Standard Event Status Register. (See “Standard Event Status
Register” on page 153.) Reading this register clears it.
Command:
*ESR?
SCPI equivalent for multichannel use:
STATus[<channel>]:STANdard[:EVENt]?
Summary of Contents for XDC
Page 2: ......
Page 3: ...Operating Manual for XDC 6000 Watt and 12000 Watt Series Digital Programmable DC Power Supply ...
Page 22: ...List of Figures xx Operating Manual for XDC Series Power Supply ...
Page 180: ...Current Sharing 6000 Watt only Operation 178 Operating Manual for XDC Series Power Supply ...
Page 216: ...SCPI Command Reference Expressions 214 Operating Manual for XDC Series Power Supply ...
Page 228: ...GPIB Performance Specifications 226 Operating Manual for XDC Series Power Supply ...
Page 253: ......