Specifications
A–4
975-0187-01-01
Temperature Specifications
Protection Features
Nominal ambient
25 °C (77 °F)
Operating range
0 – 50 °C (32 – 122 °F)
Current de-rating
approx. 2% (Imax) / °C (50 – 65 °C) (122 – 149 °F)
Storage
-40 – 80 °C (-40 – 176 °F)
Humidity
5 – 95%, RH non-condensing
Battery reverse polarity
No damage incurred by reverse polarity.
Safe non-operating battery voltage
35 VDC maximum
Over-voltage limits
The XC Series will stop charging any bank that has a
voltage greater than + 0.5 V over the temperature
compensated absorption voltage. It will restart when
this voltage is + 0.2 V.
Output current limit
XC3012:
30 – 33 ADC
XC5012:
50 – 55 ADC
XC1524:
15 – 16.5 ADC
XC2524:
25 – 27.5 ADC
Over-temperature
Internal charger temperature is measured. Unit shuts
down and restarts as follows:
•
Over-temperature shutdown at 75 °C (167 °F)
•
Over-temperature restart at 70 °C (158 °F)
Current derating in ambient
temperatures
Rated current to 50 °C (122 °F)
2%/ °C derating above 50 °C (122 °F)
Battery over-temperature
protection
Battery temperature, as sensed by the battery
temperature sensor (if installed), results in the
charger no longer charging the individual battery or
bank at a battery temperature of 55 °C (132 °F).
XC_Charger_Owner.book Page 4 Friday, August 12, 2005 3:23 PM
Summary of Contents for XC1524
Page 2: ...XC_Charger_Owner book Page 2 Friday August 12 2005 3 23 PM...
Page 10: ...viii XC_Charger_Owner book Page viii Friday August 12 2005 3 23 PM...
Page 58: ...3 16 XC_Charger_Owner book Page 16 Friday August 12 2005 3 23 PM...
Page 68: ...4 10 XC_Charger_Owner book Page 10 Friday August 12 2005 3 23 PM...
Page 74: ...A 6 XC_Charger_Owner book Page 6 Friday August 12 2005 3 23 PM...
Page 79: ...XC_Charger_Owner book Page 5 Friday August 12 2005 3 23 PM...